Rockwell 1783-NATR CVE-2025-7330
HIGHAttack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessPhish admin with crafted link
-
ExploitAdmin's authenticated browser loads forgery
-
ExecutionForged request hits unprotected config form
-
ImpactNAT router configuration silently modified
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V3 - Web Frontend Security Anti-CSRF tokens, SameSite cookies
MITRE ATT&CK
1 technique across 1 tactic: Initial Access The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires an administrator to be actively authenticated to the 1783-NATR web management interface AND to be tricked into visiting an attacker-crafted link/page while that session is valid (UI:A). The specific prerequisite is the affected configuration form's lack of an anti-CSRF token, allowing cross-origin state-changing requests to succeed. Limiting factors: no attacker authentication or privileges are needed (PR:N), but the attack cannot proceed without the victim admin's interaction and an active admin session; it also depends on management-interface reachability from the admin's browser. There is no confidentiality exposure (VC:N) - only configuration integrity/availability is at risk. |
| Impact | Signals point consistently toward a LOW real-world priority despite the 7.0 (High) CVSS 4.0 base score. The vector (AV:N/AC:L/AT:N/PR:N/UI:A) shows a network-reachable, low-complexity attack but one that is fundamentally gated on active user interaction (UI:A) - a logged-in administrator must be socially engineered into visiting an attacker-crafted link, which is the defining limitation of any CSRF (CWE-352) issue. EPSS reinforces low urgency at 0.21% (10th percentile), and the vulnerability is NOT in CISA KEV, with no public POC identified, so there is no evidence of active or imminent exploitation. The impact profile is credible - VI:H/VA:H (no confidentiality impact, VC:N) matches 'unintended configuration modification' of an industrial NAT router - but the reliance on a human victim plus the niche OT deployment footprint keeps aggregate risk modest. No conflicting signals of note: the CVSS vector, EPSS, absence of KEV/POC, and the description all agree this is a genuine but hard-to-mass-exploit, interaction-dependent flaw rather than a wormable or opportunistic threat. The main residual risk is in high-value OT environments where a single compromised router config could affect network segmentation. |
| Exploit ScenarioDerived | An attacker crafts a malicious web page or link containing a forged request targeting the 1783-NATR management form and lures a currently authenticated administrator into opening it (e.g., via phishing). Because the form lacks CSRF protection, the admin's authenticated browser session silently submits the attacker-chosen configuration change. No public exploit code is known, and success depends on the admin being logged in and taking the bait (UI:A). |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 08, 2026
Configuration modification in Rockwell Automation 1783-NATR firmware can be triggered by a remote attacker who convinces an authenticated administrator to visit a crafted link. The affected form lacks a CSRF token, so a cross-origin request can change device settings while the admin session is active; the attacker does not need credentials, but the administrator must interact with the crafted page. No public exploit code has been identified, EPSS is 0.21% (10th percentile), and the independent assessment rates real-world priority as low despite the 7.0 High CVSS 4.0 base score.
RemediationAI
Vendor advisory SD1756 provides the authoritative remediation; apply the firmware update it specifies, and confirm the patched firmware release in that advisory because the available input does not include an exact fixed version. If a fixed firmware version is not immediately available, restrict access to the 1783-NATR web management interface to trusted administrator networks or a dedicated jump host, and block HTTP/HTTPS management access from general user or Internet-facing networks; trade-offs include reduced remote-management convenience and need for network ACL maintenance. Administrators should log out of the web interface when not actively configuring the device, avoid browsing untrusted sites in the same browser session, and monitor device configuration changes for unexpected modifications; these controls reduce CSRF exploitation opportunities but do not replace vendor patching.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
CVE-2025-7330 is a CWE-352 Cross-Site Request Forgery flaw in the web management interface of Rockwell Automation 1783-NATR firmware, identified by CPE cpe:2.3:o:rockwellautomation:1783-natr_firmware:*:*:*:*:*:*:*:* (version wildcard, so all firmware revisions are potentially in scope). The root cause is the absence of an anti-CSRF token or equivalent origin validation on a state-changing configuration form; a browser with an active admin session will automatically include the admin's cookies in a forged request, allowing settings to be altered without the admin's intent. The CVSS 4.0 vector shows AV:N, AC:L, PR:N, UI:A, VC:N, VI:H, VA:H, meaning the attacker needs no authentication but must induce an administrator to interact while authenticated; the independent CVSS 3.1 assessment is AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H, reinforcing that only configuration integrity and availability are impacted, not confidentiality. Rockwell PSIRT has published advisory SD1756 for this issue.
Know when 1783 Natr Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N
Network-reachable CSRF with no attacker privileges (PR:N) but mandatory admin interaction (UI:R); config change harms integrity and availability (I:H/A:H), no data disclosure (C:N).
Primary rating from Vendor (rockwellautomation).
CVSS VectorVendor: rockwellautomation
DescriptionCVE.org
A cross-site request forgery security issue exists in the product and version listed. The vulnerability stems from missing CSRF checks on the impacted form. This allows for unintended configuration modification if an attacker can convince a logged in admin to visit a crafted link.
Executive ViewAI
Rockwell Automation 1783-NATR firmware contains a configuration-integrity vulnerability that could allow unauthorized changes to network routing settings on affected industrial devices if an administrator is induced to visit a crafted link. Leadership should care because these devices often enforce segmentation in OT environments, and a successful attack could disrupt operations and require manual restoration, although no public exploit has been identified at time of analysis and exploitation requires administrator interaction.
No vendor-released patch identified at time of analysis. Interim mitigations include restricting management access to dedicated trusted admin workstations, requiring administrators to log out after configuration and avoid browsing untrusted sites while authenticated, enabling configuration-change monitoring on 1783-NATR devices, and enforcing network segmentation to limit exposure of the management interface.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Cross-Site Request Forgery exploits the automatic credential inclusion behavior of web browsers.
Affected Products (CPE)CVE.org
More in 1783 Natr Firmware
View allUnauthenticated attackers who can reach the management or critical-function interfaces of a Rockwell Automation 1783-NAT
Stored cross-site scripting in Rockwell Automation's 1783-NATR firmware allows an attacker who already holds administrat
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB