DescriptionCVE.org

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.

AnalysisAI

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise. Affected products include: Comfast Cf-Xr11 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.