F5 BIG-IP CVE-2025-53868
HIGHAttack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAuthenticate as privileged admin via SCP/SFTP
-
DeliveryInvoke undisclosed commands in Appliance mode
-
ExploitBypass restricted-shell restrictions
-
ExecutionExecute commands on appliance
-
ImpactFull control of BIG-IP configuration and data
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK
2 techniques across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires (1) the BIG-IP to be running in Appliance mode (a non-default, deliberately hardened lockdown configuration), and (2) the attacker to already possess a highly privileged, authenticated administrative account with SCP and SFTP access to the device. The vulnerability is the ability to use undisclosed commands over the SCP/SFTP channel to escape Appliance mode's restricted shell. Strong limiting factors: PR:H means no unprivileged or unauthenticated path exists, and systems not operating in Appliance mode are outside the stated condition. Software versions past End of Technical Support (EoTS) were not evaluated by the vendor and should be treated as out of assessed scope. |
| Impact | This is a genuine but bounded risk. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:H/UI:N, VC:H/VI:H/VA:N) scores 8.5 (High), but the defining constraint is PR:H - the attacker must already be a highly privileged, authenticated administrator with SCP/SFTP access to a BIG-IP running in Appliance mode. The severity therefore reflects a trust-boundary bypass (defeating Appliance mode hardening) rather than an externally reachable flaw; a lone external attacker cannot trigger it without first obtaining privileged credentials. The EPSS score of 0.44% (37th percentile) is low, consistent with the high privilege barrier and the absence of any public exploit, and the CVE is not listed in CISA KEV - so there is no public exploit identified at time of analysis and no evidence of active exploitation. The low EPSS and the high-privilege requirement reconcile cleanly rather than conflicting: this is a defense-in-depth / insider-and-post-compromise risk for hardened F5 deployments, not a mass-exploitation priority. One point to verify with the vendor: the exact 'undisclosed commands' and affected version ranges are not detailed in the provided data (F5 withholds them), so the precise scope of impacted modules should be confirmed against advisory K000151902. |
| Exploit ScenarioDerived | An attacker who has already compromised or legitimately holds a highly privileged administrative account on an F5 BIG-IP configured in Appliance mode connects over SCP/SFTP and issues undisclosed commands that are supposed to be blocked by Appliance mode's restricted shell. By escaping those restrictions the attacker regains broad command execution (CWE-78) on the appliance, defeating the hardening that Appliance mode is meant to enforce. No public proof-of-concept exploit is known at time of analysis. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 08, 2026
Appliance mode restrictions in F5 BIG-IP can be escaped by a highly privileged, authenticated administrator who already holds SCP and SFTP access to the device, allowing undisclosed commands to run outside the restricted shell that Appliance mode is designed to enforce. The flaw is a command-injection class issue (CWE-78) in the BIG-IP platform and affects the broad set of BIG-IP modules (APM, ASM/AWAF, AFM, Analytics, AAM, CGNAT, CIS, and others) only when the system is deliberately configured in Appliance mode - a non-default hardened lockdown state. Exploitation requires PR:H per the CVSS vector, meaning no unauthenticated or low-privileged path exists, and there is no public exploit identified at time of analysis; EPSS is low at 0.44% (37th percentile), and the CVE is not listed in CISA KEV. The net effect is a confidentiality and integrity impact (high C/I, no availability impact) for environments that tier a hardened Appliance-mode posture against trusted administrators.
RemediationAI
F5 has published the vendor advisory at https://my.f5.com/manage/s/article/K000151902, which is the authoritative source for the fixed releases and the exact version matrix; because the provided intelligence does not enumerate a specific patched version, treat this as 'patch available per vendor advisory' and confirm your target line against that article before upgrading, then schedule upgrades during a maintenance window given BIG-IP's role as a traffic-handling device. Recommended fix is to upgrade affected BIG-IP instances to a release F5 lists as remediated in K000151902 rather than treating Appliance mode as the compensating control, since the vulnerability is precisely the ability to escape that mode. Where immediate upgrade is not possible, reduce the attack surface by tightly restricting which administrative accounts may use SCP and SFTP (limit to the minimum set of trusted operators, disable SCP/SFTP for general admins, and prefer out-of-band management on a dedicated management network) - a trade-off that breaks file-transfer-based admin workflows and may slow troubleshooting, but does not close the underlying flaw. Audit and rotate credentials for all highly privileged accounts and review logs for unexpected commands issued over SCP/SFTP, since the vector requires an existing privileged account and detection depends on identifying anomalous use of that channel. Do not disable Appliance mode as a mitigation - that would remove the hardening boundary the CVE is about, weaken the device beyond its intended posture, and would not address the command-injection path itself. Finally, inventory any BIG-IP software that has reached EoTS, as those versions were explicitly not evaluated and therefore have no confirmed fix; they should be prioritized for replacement or migration.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
BIG-IP runs on F5's TMOS platform, and 'Appliance mode' is an optional, non-default lockdown configuration intended to harden a device that has been deployed as a sealed appliance: it restricts the administrative shell, blocks out-of-band changes and file system access, and prevents privileged users from escaping into the underlying Linux environment. The vulnerability is classified as CWE-78 (OS Command Injection): undisclosed commands reachable through the SCP and SFTP interfaces allow an attacker to execute operations that the restricted shell would otherwise refuse, thereby bypassing Appliance mode's enforcement boundary. The 4.0 vector (AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:N) and the independent CVSS 3.1 assessment (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N) agree that the attacker must be network-reachable and hold a highly privileged authenticated account, and that the outcome is high confidentiality and integrity loss with no availability impact. The CPE data confirm the issue is platform-wide across the BIG-IP product modules rather than confined to one add-on, and the vendor notes that software versions past End of Technical Support (EoTS) were not evaluated and are outside assessed scope.
Know when Big Ip Advanced Web Application Firewall gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N
PR:H because it requires an existing highly privileged admin with SCP/SFTP access; AV:N/AC:L as the channel is network-reachable and reliable; S:U and A:N since impact stays on the appliance with no availability loss.
Primary rating from Vendor (f5).
CVSS VectorVendor: f5
DescriptionCVE.org
When running in Appliance mode, a highly privileged authenticated attacker with access to SCP and SFTP may be able to bypass Appliance mode restrictions using undisclosed commands. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
Executive ViewAI
F5 BIG-IP environments using Appliance mode face a high-severity command-injection issue that could allow an authenticated, highly privileged administrator with SCP/SFTP access to bypass hardened Appliance-mode restrictions and run undisclosed commands, affecting confidentiality and integrity. Because exploitation requires existing high privilege and is limited to non-default Appliance-mode configurations, the primary concern is insider or compromised-admin abuse in regulated or high-security deployments. There is no public exploit identified at time of analysis, and no vendor-released patch is identified at time of analysis, so leadership should prioritize access restrictions, monitoring, and vendor patch tracking for these systems.
No vendor-released patch identified at time of analysis. Interim mitigations: restrict SCP/SFTP and other privileged administrative access to essential trusted personnel; enforce least privilege and MFA; enable detailed auditing and monitoring of privileged activity; validate whether Appliance mode is required and consider alternative hardening controls with F5 guidance.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
Affected Products (CPE)CVE.org
Denial of service against HTTP/2 server implementations allows remote unauthenticated attackers to exhaust server resour
F5 BIG-IP APM (Access Policy Manager) contains a remote code execution vulnerability triggered by specific malicious tra
F5 BIG-IP contains an authenticated command injection in the iControl REST API and TMOS Shell (tmsh) save command. Authe
Undisclosed requests may bypass configuration utility authentication, allowing an attacker with network access to the BI
On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.2.1, 14.1.x before 14.1.4, 13.1.x before 13.1.3.6, and 12.
An authenticated SQL injection vulnerability exists in the BIG-IP Configuration utility which may allow an authenticated
BIG-IP monitor functionality may allow an attacker to bypass access control restrictions, regardless of the port lockdow
A directory traversal vulnerability exists in the BIG-IP Configuration Utility that may allow an authenticated attacker
On version 16.0.x before 16.0.1.2, 15.1.x before 15.1.3, 14.1.x before 14.1.4.1, 13.1.x before 13.1.4, 12.1.x before 12.
On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.2.1, 14.1.x before 14.1.4, 13.1.x before 13.1.3.6, 12.1.x
On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.2.1, 14.1.x before 14.1.4, 13.1.x before 13.1.3.6, and 12.
On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.2.1, 14.1.x before 14.1.4, 13.1.x before 13.1.3.6, 12.1.x
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB