Skip to main content

Ac6 Firmware CVE-2025-50262

| EUVDEUVD-2025-19882 HIGH
Classic Buffer Overflow (CWE-120)
2025-07-03 cve@mitre.org
7.5
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Buffer copy size validation
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

Successful exploitation can lead to arbitrary code execution, denial of service, or privilege escalation depending on the memory layout and protections in place. With a CVSS score of 7.5 (HIGH), this represents a significant risk.

Exploit ScenarioDerived

An attacker sends an oversized input to a vulnerable function, overwriting the return address on the stack to redirect execution to attacker-controlled shellcode.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 16, 2026

Tenda AC6 v15.03.05.16_multi is vulnerable to Buffer Overflow in the formSetQosBand function via the list parameter.

Earlier versions of this analysis (1)
v1 Mar 16, 2026 - 02:12 CVSS 7.5

RemediationAI

Use memory-safe languages or bounds-checked functions. Enable ASLR, DEP/NX, and stack canaries. Apply vendor patches promptly.

Affected VersionsENISA

n/a n/a

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

A buffer overflow occurs when data written to a buffer exceeds its allocated size, potentially overwriting adjacent memory and corrupting program state. This vulnerability is classified as Classic Buffer Overflow (CWE-120).

Know when Ac6 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

2
PoC Detected
Jul 07, 2025 - 14:40 vuln.today
Public exploit code
CVE Published
Jul 03, 2025 - 14:15 nvd
HIGH 7.5

Executive ViewAI

Why It Matters

Organizations using Tenda AC6 v15.03.05.16_multi face notable risk from CVE-2025-50262, a buffer overflow vulnerability rated CVSS 7.5. Exploitation could allow attackers to corrupt memory, crash the application, or potentially execute arbitrary code. Proof-of-concept code is publicly available, increasing the risk of exploitation. Organizations should apply vendor updates when available and consider compensating controls in the interim.

Business Impact: High
Compensating Controls

Apply vendor patch. If immediate patching is not feasible: (1) Enable ASLR and DEP where available; (2) Implement network segmentation; (3) Monitor for exploitation indicators.

Threat Intelligence Overview

EPSS Score
0.1%
Top 75% exploitable
Exploit
POC
Public exploit code exists
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
High

Priority Score

58
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +38
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

CVE-2024-52714 CRITICAL POC
9.8 Nov 19

Tenda AC6 v2.0 v15.03.06.50 was discovered to contain a buffer overflow in the function 'fromSetSysTime. Rated critical

CVE-2025-25343 CRITICAL POC
9.8 Feb 12

Tenda AC6 V15.03.05.16 firmware has a buffer overflow vulnerability in the formexeCommand function. Rated critical sever

CVE-2025-29031 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the fromAddressNat function. Rated critical sever

CVE-2025-29030 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formWifiWpsOOB function. Rated critical sever

CVE-2025-29029 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function. Rated critical seve

CVE-2023-40838 CRITICAL POC
9.8 Aug 30

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability. Rate

CVE-2023-40846 CRITICAL POC
9.8 Aug 28

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998. Rated critic

CVE-2023-38937 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC

CVE-2023-38936 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,

CVE-2023-38933 CRITICAL POC
9.8 Aug 07

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0

CVE-2023-38931 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1

CVE-2023-2923 CRITICAL POC
9.8 May 27

A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Rated critical severity (CVSS 9

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy