Netgear EX8000
CVE-2025-45493
MEDIUM
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessReach EX8000 web management interface
-
DeliveryTarget action_bandwidth endpoint
-
ExploitInject shell metacharacters into iface parameter
-
ExecutionDevice executes injected OS commands
-
ImpactAttacker controls extender
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Requires network reachability to the EX8000's HTTP(S) management interface and the ability to invoke the action_bandwidth handler with a malicious iface parameter containing shell metacharacters; only firmware V1.0.0.126 is identified as affected. The published vector claims no privileges (PR:N), but these Netgear extender CGI endpoints normally require an authenticated admin session, which - if true - is the primary limiting factor and would confine exploitation to attackers who have already authenticated or who reach an exposed/default-credential device on the local network rather than the open Internet. Authentication requirement is not confirmed from the available data. |
| Impact | Signals are mixed and point to a moderate, not urgent, priority. CVSS 3.1 is 6.5 (medium) with the published vector AV:N/AC:L/PR:N/UI:N/C:L/I:L/A:N - note this vector is internally questionable: a classic command-injection flaw (CWE-77) in a router's action_bandwidth handler normally yields full command execution (C:H/I:H), so the partial C:L/I:L/A:N impact and especially PR:N are suspect, since these Netgear extender CGI endpoints typically sit behind the admin web session - verify authentication requirement with the vendor. EPSS is low at 0.90% (59th percentile), indicating no broad automated exploitation is expected. The vulnerability is NOT in CISA KEV, so there is no confirmed active exploitation. A public PoC reference exists (a PDF write-up and an mp4 demonstration on GitHub) but it is not verified as working, weaponized exploit code. The vuln.today decision label is 'this_month', consistent with a real-but-not-emergency issue: a reproducible injection in a consumer mesh extender with demonstration material, but low exploitation probability and no in-the-wild evidence. Net: treat as a scheduled-patch item, prioritized above routine but below KEV/emergency work. |
| Exploit ScenarioDerived | An attacker with reachability to the EX8000's web management interface sends a crafted request to the action_bandwidth function with shell metacharacters injected into the iface parameter, causing the device to execute attacker-supplied OS commands. A public PoC reference (PDF and video demonstration) exists showing the injection, though it is not verified as a packaged working exploit. Given the AV:N/AC:L vector, exploitation is low-complexity once the attacker can reach the management endpoint. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 28, 2026
Command injection in the Netgear EX8000 range extender's action_bandwidth handler allows remote attackers to pass a crafted iface parameter into a shell command, potentially achieving arbitrary command execution on devices running firmware V1.0.0.126. The severity signals are mixed: the published record scores it 6.5 with no privileges required, while independent review rates confidentiality, integrity and availability impact as high but assumes an authenticated admin session, and that authentication requirement is not confirmed from the available data. There is no CISA KEV listing and EPSS is 0.90% (59th percentile); a public proof-of-concept reference and a demonstration video exist in a third-party GitHub repository but are not verified as working exploit code, and the priority label is this_month.
RemediationAI
No vendor-released patch identified at time of analysis: the references contain only a third-party PoC repository and a VulDB entry, with no Netgear advisory and no fixed firmware version stated. Owners should check Netgear's support pages for the EX8000 and monitor for a firmware release above V1.0.0.126, but no such release is confirmed by the data here, so do not assume updating resolves the issue until the vendor documents it. Until then, compensating controls follow from the exploitation preconditions: confine reachability to the extender's HTTP(S) management interface to a trusted LAN segment or management VLAN and block it from untrusted networks and from WAN exposure, accepting that this does not help if an attacker is already inside the trusted segment; replace any default administrative credentials with unique strong ones and restrict who holds them, which limits exposure if, as independently assessed, the action_bandwidth handler requires an authenticated admin session, but provides no protection if the published PR:N vector is correct; and monitor or restrict access to the action_bandwidth CGI endpoint at the network layer where an inline device permits it, with the trade-off that blocking the handler may break legitimate bandwidth-statistics features in the admin UI. Because a public proof-of-concept reference exists, treat any EX8000 with a reachable management interface as a candidate for review and log inspection.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The flaw is a classic OS command injection (CWE-77) in the web management interface of the Netgear EX8000 range extender. The affected component is the action_bandwidth CGI handler, which accepts an iface parameter and does not adequately neutralize shell metacharacters before that value reaches a system command; the trigger is invoking the handler with an iface value containing shell metacharacters. Because the handler lives in the device's HTTP(S) management surface, reachability to that interface is the key exposure precondition. CPE data identifies only the firmware image - cpe:2.3:o:netgear:ex8000_firmware:1.0.0.126 - as affected, with no confirmation in the available sources about other firmware branches. Assessment of prerequisites is unresolved: the supplied NVD-style vector uses PR:N (no privileges), whereas the independent assessment applies PR:H on the reasoning that these extender CGI endpoints normally require an authenticated admin session and therefore raises C/I/A impact to High; the sources do not settle which is correct, and the authentication requirement should be treated as unconfirmed. Netgear extender management endpoints are typically reachable from the local network segment on which the device sits, so the practical attack path depends heavily on whether the interface is exposed beyond that segment.
Know when Ex8000 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
Command injection yields full device command execution (C:H/I:H/A:H); AV:N/AC:L for the network web endpoint, but PR:H because the action_bandwidth admin CGI normally requires an authenticated session.
Primary rating from Vendor (mitre).
CVSS VectorVendor: mitre
DescriptionCVE.org
Netgear EX8000 V1.0.0.126 is vulnerable to Command Injection via the iface parameter in the action_bandwidth function.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
Affected Products (CPE)CVE.org
More in Ex8000 Firmware
View allNetgear EX8000 V1.0.0.126 is vulnerable to Command Injection via the Iface parameter in the action_wireless function. Ra
Command injection in the Netgear EX8000 Wi-Fi range extender running firmware 1.0.0.126 lets remote attackers pass unsan
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. Rated critical severity (CVSS
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. Rated critical severity (CVSS
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. Rated critical severity (CVSS
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. Rated critical sev
Certain NETGEAR devices are affected by incorrect configuration of security settings. Rated critical severity (CVSS 9.4)
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR Nigh
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R780
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR Nigh
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R780
This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR R7800 firmware
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB