CVE-2025-10359
MEDIUMCVSS Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Lifecycle Timeline
3Description
A vulnerability was detected in Wavlink WL-WN578W2 221110. This impacts the function sub_404DBC of the file /cgi-bin/wireless.cgi. The manipulation of the argument macAddr results in os command injection. The attack can be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Analysis
A vulnerability was detected in Wavlink WL-WN578W2 221110. Rated medium severity (CVSS 6.9), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical Context
This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. A vulnerability was detected in Wavlink WL-WN578W2 221110. This impacts the function sub_404DBC of the file /cgi-bin/wireless.cgi. The manipulation of the argument macAddr results in os command injection. The attack can be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Wavlink Wl-Wn578W2 Firmware.
Affected Products
Wavlink Wl-Wn578W2 Firmware.
Remediation
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.