Ac1206 Firmware
CVE-2024-9793
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 5.3 (MEDIUM). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | A remote attacker could inject arbitrary commands into system command execution by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda Ac1206 Firmware. Version information: up to 15.03.06.23..
Know when Ac1206 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
Primary rating from Vendor (vuldb) · only source for this CVE.
CVSS VectorVendor: vuldb
DescriptionCVE.org
A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
Affected Products (CPE)CVE.org
More in Ac1206 Firmware
View allTenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were
Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow i
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto paramet
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetIpMacBind. Rated critical s
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the PPPOEPassword parameter in the function for
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB