A denial-of-service vulnerability exists via the CIP/Modbus port in the Rockwell Automation Micro850/870 (2080 -L50E/2080 -L70E). If exploited, the CIP/Modbus communication may be disrupted for short duration.
AnalysisAI
A denial-of-service vulnerability exists via the CIP/Modbus port in the Rockwell Automation Micro850/870 (2080 -L50E/2080 -L70E). Rated medium severity (CVSS 6.9), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Uncontrolled Resource Consumption (CWE-400), which allows attackers to cause denial of service by exhausting system resources. A denial-of-service vulnerability exists via the CIP/Modbus port in the Rockwell Automation Micro850/870 (2080 -L50E/2080 -L70E). If exploited, the CIP/Modbus communication may be disrupted for short duration.
Affected ProductsAI
See vendor advisory for affected versions.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement rate limiting, set resource quotas, validate input sizes, use timeouts.
In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to int
All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. Rated high s
The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability. Rated critical
In affected versions, a path traversal exists when processing a message in Rockwell Automation's ThinManager ThinServer.
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. Rated critical severity (CVSS 9.8), this vulnerability is
An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L
Rockwell Automation MicroLogix 1400 PLC 1766-L32BWA, 1766-L32AWA, 1766-L32BXB, 1766-L32BWAA, 1766-L32AWAA, and 1766-L32B
The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, Due to imprope
The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware imag
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. Rated high severity (CVSS 8.1), this vul
In affected versions, path traversal exists when processing a message of type 8 in Rockwell Automation's ThinManager Thi
An exploitable denial of service vulnerability exists in the ENIP Request Path Logical Segment functionality of Allen-Br
Same weakness CWE-400 – Uncontrolled Resource Consumption
View allSame technique Denial Of Service