Skip to main content

Connext Professional CVE-2024-52058

HIGH
OS Command Injection (CWE-78)
2024-12-13 3f572a00-62e2-4423-959a-7ea25eff1638
8.6
CVSS 4.0 · Vendor: 3f572a00-62e2-4423-959a-7ea25eff1638
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 8.6 (HIGH). Attack characteristics: local attack vector, low complexity, no privileges required, no user interaction not required.

Exploit ScenarioDerived

A local attacker with access to the system could execute arbitrary operating system commands on the host. No authentication is required to exploit this vulnerability.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.6% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in RTI Connext Professional (System Designer) allows OS Command Injection.0.0 before 7.3.0.2,. Rated high severity (CVSS 8.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in RTI Connext Professional (System Designer) allows OS Command Injection.0.0 before 7.3.0.2, from 6.1.0 before 6.1.2.19. Affected products include: Rti Connext Professional. Version information: before 7.3.0.2.

Know when Connext Professional gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (3f572a00-62e2-4423-959a-7ea25eff1638) PRIMARY 8.6 HIGH
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (3f572a00-62e2-4423-959a-7ea25eff1638) · only source for this CVE.

CVSS VectorVendor: 3f572a00-62e2-4423-959a-7ea25eff1638

Attack Vector
Local
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in RTI Connext Professional (System Designer) allows OS Command Injection.This issue affects Connext Professional: from 7.0.0 before 7.3.0.2, from 6.1.0 before 6.1.2.19.

Threat Intelligence Overview

EPSS Score
0.6%
Top 54% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.6%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation· derived
None
System Exposure· derived
Small
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

44
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +43
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Affected Products (CPE)CVE.org

cpe:2.3:a:rti:connext_professional:*:*:*:*:*:*:*:*
cpe:2.3:a:rti:connext_professional:*:*:*:*:*:*:*:*
CVE-2026-7866 CRITICAL
10.0 Sep 22

A stack-based buffer overflow in the RTI Connext Professional Core Libraries lets a remote, unauthenticated attacker cor

CVE-2026-2467 CRITICAL
9.2 Jun 17

Remote heap-based buffer overflow in RTI Connext Professional Core Libraries allows unauthenticated network attackers to

CVE-2026-3894 CRITICAL
9.2 Jun 17

Out-of-bounds read in RTI Connext Professional Core Libraries allows remote unauthenticated attackers to read beyond int

CVE-2026-18461 CRITICAL
9.2 Sep 22

Format-string injection in RTI Connext Professional Core Libraries (versions 7.5.0 before 7.7.0.1 and 7.3.0.10 before 7.

CVE-2024-52057 CRITICAL
9.1 Dec 13

Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in RTI Connext Profes

CVE-2026-7300 HIGH
8.8 Jun 17

Remote denial of service and partial data exposure in RTI Connext Professional's Web Integration Service results from a

CVE-2025-14543 HIGH
8.8 Apr 30

XML External Entity (XXE) injection in RTI Connext Professional's Core Libraries allows remote unauthenticated attackers

CVE-2026-4374 HIGH
8.8 Apr 01

XML External Entity (XXE) injection in RTI Connext Professional routing and service components allows remote unauthentic

CVE-2026-18459 HIGH
8.7 Sep 22

Remote, unauthenticated attackers who can reach the DDS/RTPS data bus of an application built on RTI Connext Professiona

CVE-2025-4993 HIGH
8.3 Sep 23

Untrusted Pointer Dereference vulnerability in RTI Connext Professional (Core Libraries) allows Pointer Manipulation.4.0

CVE-2025-1255 HIGH
8.3 Sep 23

Untrusted Pointer Dereference vulnerability in RTI Connext Professional (Core Libraries) allows Pointer Manipulation.4.0

CVE-2025-10450 HIGH
8.3 Dec 16

Network traffic sniffing in RTI Connext Professional 7.2.0-7.3.0 and 7.4.0-7.6.x exposes private personal information to

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy