Oncell G3470A Lte Us Firmware
CVE-2024-4641
CRITICAL
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Format string safety
|
| Impact | CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. |
| Exploit ScenarioDerived | This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the critical-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-134. OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service. Affected products include: Moxa Oncell G3470A-Lte-Us-T Firmware, Moxa Oncell G3470A-Lte-Eu Firmware, Moxa Oncell G3470A-Lte-Eu-T Firmware, Moxa Oncell G3470A-Lte-Us Firmware.
Know when Oncell G3470A Lte Us Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.
Affected Products (CPE)NVD
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutrali
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutrali
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds che
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB