Skip to main content

Dir 822 Firmware CVE-2024-33344

CRITICAL
Command Injection (CWE-77)
2024-04-26 cve@mitre.org
9.8
CVSS 3.1 · Vendor: mitre
Share

Severity by source

Vendor (mitre) PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from Vendor (mitre) · only source for this CVE.

CVSS VectorVendor: mitre

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Apr 26, 2024 - 18:15 cve.org
CRITICAL 9.8

DescriptionCVE.org

D-Link DIR-822+ V1.0.5 was found to contain a command injection in ftext function of upload_firmware.cgi, which allows remote attackers to execute arbitrary commands via shell.

AnalysisAI

D-Link DIR-822+ V1.0.5 was found to contain a command injection in ftext function of upload_firmware.cgi, which allows remote attackers to execute arbitrary commands via shell. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. D-Link DIR-822+ V1.0.5 was found to contain a command injection in ftext function of upload_firmware.cgi, which allows remote attackers to execute arbitrary commands via shell. Affected products include: Dlink Dir-822\+ Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.

Share

CVE-2024-33344 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy