Skip to main content

Solutions Enabler Virtual Appliance CVE-2024-25955

HIGH
OS Command Injection (CWE-78)
2024-03-28 security_alert@emc.com
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Mar 28, 2024 - 19:15 nvd
HIGH 8.8

DescriptionNVD

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.

AnalysisAI

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity. Affected products include: Dell Powermax Eem, Dell Solutions Enabler Virtual Appliance, Dell Unisphere For Powermax Virtual Appliance. Version information: prior to 9.2.4.9.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.

CVE-2024-25946 HIGH
8.8 Mar 28

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. Rated high severity (CVSS 8.8),

CVE-2022-31233 HIGH
8.0 Aug 31

Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. Rated high severity (CVSS

CVE-2021-21531 HIGH
7.8 Apr 30

Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. Rated high severity

CVE-2023-48671 HIGH
7.5 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain an information disclosure vulnerability. Rated high severity (CVSS

CVE-2023-48660 HIGH
7.5 Dec 14

Dell vApp Manger, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. Rated high severity (CVSS 7.5)

CVE-2025-36595 HIGH
7.2 Jun 27

A remote code execution vulnerability (CVSS 7.2). High severity vulnerability requiring prompt remediation.

CVE-2023-48665 HIGH
7.2 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. Rated high severity (CVSS 7.2),

CVE-2023-48664 HIGH
7.2 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. Rated high severity (CVSS 7.2),

CVE-2023-48663 HIGH
7.2 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. Rated high severity (CVSS 7.2),

CVE-2023-48662 HIGH
7.2 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. Rated high severity (CVSS 7.2),

CVE-2023-48661 MEDIUM
4.9 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. Rated medium severity (CVSS 4

Share

CVE-2024-25955 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy