Skip to main content

Vigor300b Firmware CVE-2024-12986

MEDIUM
Command Injection (CWE-77)
2024-12-27 cna@vuldb.com
6.9
CVSS 4.0 · Vendor: vuldb
Share

Severity by source

Vendor (vuldb) PRIMARY
6.9 MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from Vendor (vuldb) · only source for this CVE.

CVSS VectorVendor: vuldb

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

1
CVE Published
Dec 27, 2024 - 16:15 cve.org
MEDIUM 6.9

DescriptionCVE.org

A vulnerability, which was classified as critical, has been found in DrayTek Vigor2960 and Vigor300B 1.5.1.3/1.5.1.4. This issue affects some unknown processing of the file /cgi-bin/mainfunction.cgi/apmcfgupptim of the component Web Management Interface. The manipulation of the argument session leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.5.1.5 is able to address this issue. It is recommended to upgrade the affected component.

AnalysisAI

A vulnerability, which was classified as critical, has been found in DrayTek Vigor2960 and Vigor300B 1.5.1.3/1.5.1.4.cgi/apmcfgupptim of the component Web Management Interface. Rated medium severity (CVSS 6.9), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. A vulnerability, which was classified as critical, has been found in DrayTek Vigor2960 and Vigor300B 1.5.1.3/1.5.1.4.cgi/apmcfgupptim of the component Web Management Interface. The manipulation of the argument session leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.5.1.5 is able to address this issue. It is recommended to upgrade the affected component. Affected products include: Draytek Vigor300B Firmware, Draytek Vigor2960 Firmware. Version information: version 1.5.1.5.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.

CVE-2020-15415 CRITICAL POC
9.8 Jun 30

On DrayTek Vigor3900, Vigor2960, and Vigor300B devices before 1.5.1, cgi-bin/mainfunction.cgi/cvmcfgupload allows remote

CVE-2020-14473 CRITICAL POC
9.8 Jun 24

Stack-based buffer overflow vulnerability in Vigor3900, Vigor2960, and Vigor300B with firmware before 1.5.1.1. Rated cri

CVE-2020-14472 CRITICAL POC
9.8 Jun 24

On Draytek Vigor3900, Vigor2960, and Vigor 300B devices before 1.5.1.1, there are some command-injection vulnerabilities

CVE-2020-14993 CRITICAL POC
9.8 Jun 23

A stack-based buffer overflow on DrayTek Vigor2960, Vigor3900, and Vigor300B devices before 1.5.1.1 allows remote attack

CVE-2020-10828 CRITICAL POC
9.8 Mar 26

A stack-based buffer overflow in cvmd on Draytek Vigor3900, Vigor2960, and Vigor300B devices before 1.5.1 allows remote

CVE-2020-10827 CRITICAL POC
9.8 Mar 26

A stack-based buffer overflow in apmd on Draytek Vigor3900, Vigor2960, and Vigor300B devices before 1.5.1 allows remote

CVE-2020-10826 CRITICAL POC
9.8 Mar 26

/cgi-bin/activate.cgi on Draytek Vigor3900, Vigor2960, and Vigor300B devices before 1.5.1 allows remote attackers to ach

CVE-2020-10825 CRITICAL POC
9.8 Mar 26

A stack-based buffer overflow in /cgi-bin/activate.cgi while base64 decoding ticket parameter on Draytek Vigor3900, Vigo

CVE-2020-10824 CRITICAL POC
9.8 Mar 26

A stack-based buffer overflow in /cgi-bin/activate.cgi through ticket parameter on Draytek Vigor3900, Vigor2960, and Vig

CVE-2020-10823 CRITICAL POC
9.8 Mar 26

A stack-based buffer overflow in /cgi-bin/activate.cgi through var parameter on Draytek Vigor3900, Vigor2960, and Vigor3

CVE-2020-8515 CRITICAL POC
9.8 Feb 01

DrayTek Vigor2960 1.3.1_Beta, Vigor3900 1.4.4_Beta, and Vigor300B 1.3.3_Beta, 1.4.2.1_Beta, and 1.4.4_Beta devices allow

CVE-2024-43027 HIGH POC
8.0 Aug 21

DrayTek Vigor 3900 before v1.5.1.5_Beta, DrayTek Vigor 2960 before v1.5.1.5_Beta and DrayTek Vigor 300B before v1.5.1.5_

Share

CVE-2024-12986 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy