Netact
CVE-2023-26057
MEDIUM
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Lifecycle Timeline
1DescriptionNVD
An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to the Configuration Dashboard page. Input validation and a proper XML parser configuration are missing. For an external attacker, it is very difficult to exploit this, because a few dynamically created parameters such as Jsession-id, a CSRF token, and an Nxsrf token would be needed. The attack can realistically only be performed by an internal user.
AnalysisAI
An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to the Configuration Dashboard page. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as XML External Entity (XXE) (CWE-611), which allows attackers to read arbitrary files or perform SSRF through XML processing. An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to the Configuration Dashboard page. Input validation and a proper XML parser configuration are missing. For an external attacker, it is very difficult to exploit this, because a few dynamically created parameters such as Jsession-id, a CSRF token, and an Nxsrf token would be needed. The attack can realistically only be performed by an internal user. Affected products include: Nokia Netact. Version information: before 22.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Disable external entity processing in XML parsers, use JSON instead of XML where possible.
An issue was discovered in Nokia NetAct 18A. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitabl
An issue was discovered in Nokia NetAct 18A. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitabl
An issue was discovered in Nokia NetAct before 22 FP2211. Rated high severity (CVSS 8.8), this vulnerability is remotely
An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to a Performance Manager page. Rated me
An issue was discovered in Nokia NetAct before 22 SP1037. Rated medium severity (CVSS 5.4), this vulnerability is remote
An issue was discovered in Nokia NetAct before 22 FP2211. Rated medium severity (CVSS 5.4), this vulnerability is remote