Skip to main content

Control CVE-2023-25719

HIGH
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') (CWE-74)
2023-02-13 cve@mitre.org
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Feb 13, 2023 - 20:15 nvd
HIGH 8.8

DescriptionNVD

ConnectWise Control before 22.9.10032 (formerly known as ScreenConnect) fails to validate user-supplied parameters such as the Bin/ConnectWiseControl.Client.exe h parameter. This results in reflected data and injection of malicious code into a downloaded executable. The executable can be used to execute malicious queries or as a denial-of-service vector. NOTE: this CVE Record is only about the parameters, such as the h parameter (this CVE Record is not about the separate issue of signed executable files that are supposed to have unique configurations across customers' installations).

AnalysisAI

ConnectWise Control before 22.9.10032 (formerly known as ScreenConnect) fails to validate user-supplied parameters such as the Bin/ConnectWiseControl.Client.exe h parameter. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-74. ConnectWise Control before 22.9.10032 (formerly known as ScreenConnect) fails to validate user-supplied parameters such as the Bin/ConnectWiseControl.Client.exe h parameter. This results in reflected data and injection of malicious code into a downloaded executable. The executable can be used to execute malicious queries or as a denial-of-service vector. NOTE: this CVE Record is only about the parameters, such as the h parameter (this CVE Record is not about the separate issue of signed executable files that are supposed to have unique configurations across customers' installations). Affected products include: Connectwise Control. Version information: before 22.9.10032.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2023-25719 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy