Skip to main content

Ca300 Poe Firmware CVE-2023-24142

CRITICAL
Command Injection (CWE-77)
2023-02-03 cve@mitre.org
9.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available.

Exploit ScenarioDerived

A remote attacker could inject arbitrary commands into system command execution by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

Act Now Prioritize within 24-48h. Why: CRITICAL severity + public POC available.
No patch listed yet 1.9% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingSize parameter in the setNetworkDiag function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingSize parameter in the setNetworkDiag function. Affected products include: Totolink Ca300-Poe Firmware.

Know when Ca300 Poe Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingSize parameter in the setNetworkDiag function.

Threat Intelligence Overview

EPSS Score
1.9%
Top 22% exploitable
Exploit
POC
Public exploit code exists
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC Yes
EPSS 1.9%
Patch available No
Active threat No
Deciding rule
CRITICAL severity + public POC available
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

71
Low Medium High Critical
KEV: 0
EPSS: +2
CVSS: +49
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Affected Products (CPE)NVD

cpe:2.3:o:totolink:ca300-poe_firmware:6.2c.884:*:*:*:*:*:*:*
CVE-2023-24161 CRITICAL POC
9.8 Feb 14

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the webWlanIdx parameter in

CVE-2023-24160 CRITICAL POC
9.8 Feb 14

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the admuser parameter in th

CVE-2023-24159 CRITICAL POC
9.8 Feb 14

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the admpass parameter in th

CVE-2023-24149 CRITICAL POC
9.8 Feb 03

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a hard code password for root which is stored in the component /e

CVE-2023-24148 CRITICAL POC
9.8 Feb 03

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the FileName parameter in t

CVE-2023-24146 CRITICAL POC
9.8 Feb 03

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the minute parameter in the

CVE-2023-24145 CRITICAL POC
9.8 Feb 03

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the plugin_version paramete

CVE-2023-24144 CRITICAL POC
9.8 Feb 03

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the hour parameter in the s

CVE-2023-24143 CRITICAL POC
9.8 Feb 03

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagTracertHop param

CVE-2023-24141 CRITICAL POC
9.8 Feb 03

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingTimeOut para

CVE-2023-24140 CRITICAL POC
9.8 Feb 03

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingNum paramete

CVE-2023-24139 CRITICAL POC
9.8 Feb 03

TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagHost parameter i

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy