Skip to main content

6Gk5204 0Ba00 2Mb2 Firmware CVE-2022-46352

HIGH
Uncontrolled Resource Consumption (CWE-400)
2022-12-13 productcert@siemens.com
7.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

1
CVE Published
Dec 13, 2022 - 16:15 nvd
HIGH 7.5

DescriptionNVD

A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). Specially crafted PROFINET DCP packets could cause a denial of service condition of affected products.

AnalysisAI

A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Uncontrolled Resource Consumption vulnerability could allow attackers to cause denial of service by exhausting system resources.

Technical ContextAI

This vulnerability is classified as Uncontrolled Resource Consumption (CWE-400), which allows attackers to cause denial of service by exhausting system resources. A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). Specially crafted PROFINET DCP packets could cause a denial of service condition of affected products. Affected products include: Siemens 6Gk5204-0Ba00-2Mb2 Firmware, Siemens 6Gk5204-0Ba00-2Kb2 Firmware, Siemens 6Gk5204-0Bs00-2Na3 Firmware, Siemens 6Gk5204-0Bs00-3La3 Firmware, Siemens 6Gk5204-0Bs00-3Pa3 Firmware.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Implement rate limiting, set resource quotas, validate input sizes, use timeouts.

Share

CVE-2022-46352 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy