Skip to main content

Conprosys Hmi System CVE-2022-44456

CRITICAL
OS Command Injection (CWE-78)
2022-12-19 vultures@jpcert.or.jp
9.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required.

Exploit ScenarioDerived

A remote attacker could execute arbitrary operating system commands on the host by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 69.9% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

CONPROSYS HMI System (CHS) Ver.3.4.4?and earlier allows a remote unauthenticated attacker to execute an arbitrary OS command on the server where the product is running by sending a specially crafted. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This OS Command Injection vulnerability could allow attackers to execute arbitrary operating system commands on the host.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. CONPROSYS HMI System (CHS) Ver.3.4.4?and earlier allows a remote unauthenticated attacker to execute an arbitrary OS command on the server where the product is running by sending a specially crafted request. Affected products include: Contec Conprosys Hmi System.

Know when Conprosys Hmi System gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

CONPROSYS HMI System (CHS) Ver.3.4.4?and earlier allows a remote unauthenticated attacker to execute an arbitrary OS command on the server where the product is running by sending a specially crafted request.

Threat Intelligence Overview

EPSS Score
69.9%
Top 1% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 69.9%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

119
Low Medium High Critical
KEV: 0
EPSS: +70
CVSS: +49
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Affected Products (CPE)NVD

cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*
CVE-2023-2758 MEDIUM POC
5.3 May 31

A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. Rated medium severity

CVE-2023-28657 HIGH
8.8 Jun 01

Improper access control vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. Rated high severity

CVE-2023-28713 HIGH
8.1 Jun 01

Plaintext storage of a password exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. Rated high severity (CVSS

CVE-2023-28399 HIGH
7.8 Jun 01

Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. Rate

CVE-2025-34081 HIGH
7.5 Jul 01

The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may cont

CVE-2023-22339 HIGH
7.5 Jan 20

Improper access control vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticate

CVE-2023-22331 HIGH
7.5 Jan 20

Use of default credentials vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthentic

CVE-2023-29154 HIGH
7.2 Jun 01

SQL injection vulnerability exists in the CONPROSYS HMI System (CHS) versions prior to 3.5.3. Rated high severity (CVSS

CVE-2023-22324 MEDIUM
6.5 Jan 30

SQL injection vulnerability in the CONPROSYS HMI System (CHS) Ver.3.5.0 and earlier allows a remote authenticated attack

CVE-2025-34080 MEDIUM
6.1 Jul 01

The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functi

CVE-2023-22373 MEDIUM
5.4 Jan 20

Cross-site scripting vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated att

CVE-2023-22334 MEDIUM
5.3 Jan 20

Use of password hash instead of password for authentication vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and ea

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy