Skip to main content

Sim2000 2P04G10 Firmware CVE-2022-43989

HIGH
Missing Authentication for Critical Function (CWE-306)
2022-11-01 psirt@sick.de
7.3
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.3 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
Low

Lifecycle Timeline

1
CVE Published
Nov 01, 2022 - 21:15 nvd
HIGH 7.3

DescriptionNVD

Password recovery vulnerability in SICK SIM2x00 (ARM) Partnumber 1092673 and 1081902 with firmware version < 1.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.2.0 as soon as possible (available in SICK Support Portal).

AnalysisAI

Password recovery vulnerability in SICK SIM2x00 (ARM) Partnumber 1092673 and 1081902 with firmware version < 1.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as. Rated high severity (CVSS 7.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Missing Authentication for Critical Function (CWE-306), which allows attackers to access critical functionality without authentication. Password recovery vulnerability in SICK SIM2x00 (ARM) Partnumber 1092673 and 1081902 with firmware version < 1.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.2.0 as soon as possible (available in SICK Support Portal). Affected products include: Sick Sim2000-2P04G10 Firmware, Sick Sim2500-2P03G10 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Require authentication for all sensitive operations, implement defense in depth.

Share

CVE-2022-43989 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy