Skip to main content

Go Rt Ac750 Firmware CVE-2022-36525

CRITICAL
Classic Buffer Overflow (CWE-120)
2022-08-15 cve@mitre.org
9.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Aug 15, 2022 - 17:15 nvd
CRITICAL 9.8

DescriptionNVD

D-Link Go-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Buffer Overflow via authenticationcgi_main.

AnalysisAI

D-Link Go-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Buffer Overflow via authenticationcgi_main. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Buffer Copy without Size Check (CWE-120), which allows attackers to overflow a buffer to corrupt adjacent memory. D-Link Go-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Buffer Overflow via authenticationcgi_main. Affected products include: Dlink Go-Rt-Ac750 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Always validate buffer sizes before copy operations. Use bounded functions (strncpy, snprintf). Enable compiler protections.

CVE-2024-22853 CRITICAL POC
9.8 Feb 06

D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote a

CVE-2024-22852 CRITICAL POC
9.8 Feb 06

D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. Rated c

CVE-2024-22916 CRITICAL POC
9.8 Jan 16

In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack

CVE-2023-48842 CRITICAL POC
9.8 Dec 01

D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at

CVE-2023-34800 CRITICAL POC
9.8 Jun 15

D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at

CVE-2023-26822 CRITICAL POC
9.8 Apr 01

D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at

CVE-2022-37056 CRITICAL POC
9.8 Aug 28

D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin,

CVE-2022-37055 CRITICAL POC
9.8 Aug 28

D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, h

CVE-2022-37057 CRITICAL POC
9.8 Aug 28

D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Command Injection via cgibin,

CVE-2024-27683 CRITICAL
9.8 Apr 11

D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. Rated crit

CVE-2022-36523 CRITICAL
9.8 Aug 15

D-Link Go-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to command injection via /htdocs/up

CVE-2022-36526 HIGH
7.5 Aug 15

D-Link GO-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Authentication Bypass via functi

Share

CVE-2022-36525 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy