Skip to main content

Honeywell CVE-2022-30319

HIGH
Authentication Bypass by Spoofing (CWE-290)
2022-07-28 cve@mitre.org
8.1
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Anti-spoofing controls
MITRE ATT&CK

1 technique across 1 tactic: Defense Evasion

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 8.1 (HIGH). Attack characteristics: adjacent network attack vector, low complexity, no privileges required, no user interaction not required.

Exploit ScenarioDerived

Successful exploitation could compromise the high-severity affected system.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.7% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. Rated high severity (CVSS 8.1), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-290. Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess Controls (SBC) PCD S-Bus authentication bypass issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication functions on the basis of a MAC/IP whitelist with inactivity timeout to which an authenticated client's MAC/IP is stored. UDP traffic can be spoofed to bypass the whitelist-based access control. Since UDP is stateless, an attacker capable of passively observing traffic can spoof arbitrary messages using the MAC/IP of an authenticated client. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration. Affected products include: Honeywell Saia Pg5 Controls Suite. Version information: through 2022.

Know when Honeywell gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.1 HIGH
AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None

DescriptionNVD

Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess Controls (SBC) PCD S-Bus authentication bypass issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication functions on the basis of a MAC/IP whitelist with inactivity timeout to which an authenticated client's MAC/IP is stored. UDP traffic can be spoofed to bypass the whitelist-based access control. Since UDP is stateless, an attacker capable of passively observing traffic can spoof arbitrary messages using the MAC/IP of an authenticated client. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.

Threat Intelligence Overview

EPSS Score
0.7%
Top 53% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.7%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

41
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +40
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

Affected Products (CPE)NVD

cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*
CVE-2013-0108 MEDIUM POC
6.8 Feb 24

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R

CVE-2015-0984 CRITICAL POC
10.0 Mar 31

Directory traversal vulnerability in the FTP server on Honeywell Excel Web XL1000C50 52 I/O, XL1000C100 104 I/O, XL1000C

CVE-2023-3710 CRITICAL POC
9.8 Sep 12

Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injec

CVE-2017-14263 HIGH
8.1 Sep 11

Honeywell NVR devices allow remote attackers to create a user account in the admin group by leveraging access to a guest

CVE-2017-5671 HIGH POC
8.8 Mar 29

Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x befo

CVE-2014-8269 HIGH
7.5 Dec 13

Multiple stack-based buffer overflows in (1) HWOPOSScale.ocx and (2) HWOPOSSCANNER.ocx in Honeywell OPOS Suite before 1.

CVE-2024-46453 MEDIUM POC
6.1 Sep 27

A cross-site scripting (XSS) vulnerability in the component /test/ of iq3xcite v2.31 to v3.05 allows attackers to execut

CVE-2025-2605 CRITICAL
9.9 May 02

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB

CVE-2026-3611 CRITICAL
10.0 Mar 12

Unauthenticated access to Honeywell IQ4x building controller HMI. CVSS 10.0.

CVE-2017-5140 CRITICAL
9.8 Feb 13

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-

CVE-2017-5139 CRITICAL
9.8 Feb 13

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-

CVE-2026-13249 CRITICAL
9.8 Sep 24

Unauthenticated remote code execution in Honeywell PD45 Industrial Printer firmware F10.19.010040 lets any network-reach