1DescriptionNVD
The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00.
AnalysisAI
The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Use of Hard-coded Credentials (CWE-798), which allows attackers to gain access using credentials embedded in source code. The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00. Affected products include: Yokogawa Centum Vp Firmware, Yokogawa Centum Vp Entry Firmware, Yokogawa Exaopc.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Remove hard-coded credentials, use environment variables or secrets management, rotate exposed credentials immediately.
More in Centum Vp Firmware
View allThe following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5
Directory traversal vulnerability in CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, C
CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, CENTUM VP (includes CENTUM VP Small, B
Violation of secure design principles exists in the communication of CAMS for HIS. Rated high severity (CVSS 8.8), this
CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets.
Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM
CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs:
CAMS for HIS Log Server contained in the following Yokogawa Electric products is vulnerable to uncontrolled resource con
There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products
The following Yokogawa Electric products contain insecure DLL loading issues. Rated high severity (CVSS 7.8), this vulne
'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL
'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe
Same weakness CWE-798 – Use of Hard-coded Credentials