Rbk752
CVE-2021-45537
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 6.8 (MEDIUM). Attack characteristics: adjacent network attack vector, low complexity, high privileges required, no user interaction not required. |
| Exploit ScenarioDerived | An attacker could exploit this vulnerability to inject arbitrary commands into system command execution. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Certain NETGEAR devices are affected by command injection by an authenticated user . Rated medium severity (CVSS 6.8), this vulnerability is low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. Certain NETGEAR devices are affected by command injection by an authenticated user . This affects RAX200 before 1.0.3.106, RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. Affected products include: Netgear Rax200 Firmware, Netgear Rax80 Firmware, Netgear Rax75 Firmware, Netgear Rbk752, Netgear Rbr750 Firmware. Version information: before 1.0.3.106.
Know when Rbk752 gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Certain NETGEAR devices are affected by command injection by an authenticated user . This affects RAX200 before 1.0.3.106, RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB