Fx3U Enet L Firmware
CVE-2021-20596
HIGH
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Lifecycle Timeline
1DescriptionNVD
NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS condition in communication by sending specially crafted packets. Control by MELSEC-F series PLC is not affected and system reset is required for recovery.
AnalysisAI
NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity.
Technical ContextAI
This vulnerability is classified as NULL Pointer Dereference (CWE-476), which allows attackers to crash the application by dereferencing a null pointer. NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS condition in communication by sending specially crafted packets. Control by MELSEC-F series PLC is not affected and system reset is required for recovery. Affected products include: Mitsubishielectric Fx3U-Enet-L Firmware, Mitsubishielectric Fx3U-Enet-P502 Firmware, Mitsubishielectric Fx3U-Enet Firmware. Version information: version 1.14.
RemediationAI
A vendor patch is available. Apply the latest security update as soon as possible. Check pointers before dereferencing. Use static analysis tools to detect null pointer paths.
More in Fx3U Enet L Firmware
View allMultiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, whic
Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote un
Same weakness CWE-476 – NULL Pointer Dereference
View allSame technique Null Pointer Dereference
View allShare
External POC / Exploit Code
Leaving vuln.today