Ht802 Firmware
CVE-2020-5762
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A10:2025 - Mishandling of Exceptional Conditions
ASVS 5.0
V16 - Security Logging and Error Handling Null pointer safety, defensive checks
MITRE ATT&CK
1 technique across 1 tactic: Impact The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 7.5 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | A remote attacker could crash the application by dereferencing a null pointer by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Check pointers before dereferencing. Use static analysis tools to detect null pointer paths.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as NULL Pointer Dereference (CWE-476), which allows attackers to crash the application by dereferencing a null pointer. Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field. Affected products include: Grandstream Ht801 Firmware, Grandstream Ht802 Firmware, Grandstream Ht812 Firmware, Grandstream Ht814 Firmware, Grandstream Ht818 Firmware. Version information: version 1.0.17.5.
Know when Ht802 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A null pointer dereference occurs when a program attempts to access memory through a pointer that has been set to NULL (address 0x0).
Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.
Affected Products (CPE)NVD
More in Ht802 Firmware
View allCross-Site Request Forgery (CSRF) in /cgi-bin/login on Vonage (Grandstream) HT802 devices allows attackers to authentica
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. Rated high severity
Cross-Site Request Forgery (CSRF) in the Basic Settings screen on Vonage (Grandstream) HT802 devices allows attackers to
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Rat
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in
Stored Cross-site scripting (XSS) vulnerability in /cgi-bin/config2 on Vonage (Grandstream) HT802 devices allows remote
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB