Skip to main content

Severity by source

NVD PRIMARY
5.4 MEDIUM
AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

Lifecycle Timeline

1
CVE Published
Jun 09, 2017 - 15:29 cve.org
MEDIUM 5.4

DescriptionCVE.org

A stored cross-site scripting (XSS) vulnerability in the Configuration utility device name change page in BIG-IP LTM, AAM, AFM, Analytics, APM, ASM, DNS, Edge Gateway, GTM, Link Controller, PEM, PSM, WebAccelerator, WOM and WebSafe version 12.0.0 - 12.1.2, 11.4.0 - 11.6.1, and 11.2.1 allows an authenticated user to inject arbitrary web script or HTML. Exploitation requires Resource Administrator or Administrator privileges, and it could cause the Configuration utility client to become unstable.

AnalysisAI

A stored cross-site scripting (XSS) vulnerability in the Configuration utility device name change page in BIG-IP LTM, AAM, AFM, Analytics, APM, ASM, DNS, Edge Gateway, GTM, Link Controller, PEM, PSM,. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. A stored cross-site scripting (XSS) vulnerability in the Configuration utility device name change page in BIG-IP LTM, AAM, AFM, Analytics, APM, ASM, DNS, Edge Gateway, GTM, Link Controller, PEM, PSM, WebAccelerator, WOM and WebSafe version 12.0.0 - 12.1.2, 11.4.0 - 11.6.1, and 11.2.1 allows an authenticated user to inject arbitrary web script or HTML. Exploitation requires Resource Administrator or Administrator privileges, and it could cause the Configuration utility client to become unstable. Affected products include: F5 Big-Ip Local Traffic Manager, F5 Big-Ip Application Acceleration Manager, F5 Big-Ip Advanced Firewall Manager, F5 Big-Ip Analytics, F5 Big-Ip Access Policy Manager. Version information: version 12.0.0.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.

CVE-2012-1493 HIGH POC
7.8 Jul 09

F5 BIG-IP appliances 9.x before 9.4.8-HF5, 10.x before 10.2.4, 11.0.x before 11.0.0-HF2, and 11.1.x before 11.1.0-HF3, a

CVE-2015-3628 CRITICAL POC
9.0 Dec 07

The iControl API in F5 BIG-IP LTM, AFM, Analytics, APM, ASM, Link Controller, and PEM 11.3.0 before 11.5.3 HF2 and 11.6.

CVE-2015-7547 HIGH POC
8.1 Feb 18

Multiple stack-based buffer overflows in the (1) send_dg and (2) send_vc functions in the libresolv library in the GNU C

CVE-2014-2928 HIGH POC
7.1 May 12

The iControl API in F5 BIG-IP LTM, APM, ASM, GTM, Link Controller, and PSM 10.0.0 through 10.2.4 and 11.0.0 through 11.5

CVE-2016-9244 HIGH POC
7.5 Feb 09

A BIG-IP virtual server configured with a Client SSL profile that has the non-default Session Tickets option enabled may

CVE-2025-20029 HIGH
8.7 Feb 05

F5 BIG-IP contains an authenticated command injection in the iControl REST API and TMOS Shell (tmsh) save command. Authe

CVE-2023-46747 CRITICAL POC
9.8 Oct 26

Undisclosed requests may bypass configuration utility authentication, allowing an attacker with network access to the BI

CVE-2022-1388 CRITICAL POC
9.8 May 05

On F5 BIG-IP 16.1.x versions prior to 16.1.2.2, 15.1.x versions prior to 15.1.5.1, 14.1.x versions prior to 14.1.4.6, 13

CVE-2021-22986 CRITICAL POC
9.8 Mar 31

On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.2.1, 14.1.x before 14.1.4, 13.1.x before 13.1.3.6, and 12.

CVE-2022-41622 HIGH POC
8.8 Dec 07

In all versions, BIG-IP and BIG-IQ are vulnerable to cross-site request forgery (CSRF) attacks through iControl SOAP. Ra

CVE-2022-41800 HIGH POC
8.7 Dec 07

In all versions of BIG-IP, when running in Appliance mode, an authenticated user assigned the Administrator role may be

CVE-2016-5700 CRITICAL POC
9.8 Oct 03

Virtual servers in F5 BIG-IP systems 11.5.0, 11.5.1 before HF11, 11.5.2, 11.5.3, 11.5.4 before HF2, 11.6.0 before HF8, 1

Share

CVE-2016-7469 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy