Skip to main content
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V2 - Validation and Business Logic Resource consumption limits
MITRE ATT&CK

1 technique across 1 tactic: Impact

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 5.0 (MEDIUM). Attack characteristics: network attack vector, low complexity. EPSS exploitation probability: 0.73%.

Exploit ScenarioDerived

A remote attacker could cause denial of service by exhausting system resources by sending crafted requests to the affected application.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 0.7% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. Rated medium severity (CVSS 5.0), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement rate limiting, set resource quotas, validate input sizes, use timeouts.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Uncontrolled Resource Consumption (CWE-400), which allows attackers to cause denial of service by exhausting system resources. The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny PLC control functions. Affected products include: Schneider-Electric Modicon M340 Bmx Noc 0401 Firmware, Schneider-Electric Modicon M340 Bmx Noe 0100 Firmware, Schneider-Electric Modicon M340 Bmx Noe 0100H Firmware, Schneider-Electric Modicon M340 Bmx Noe 0110 Firmware, Schneider-Electric Modicon M340 Bmx Noe 0110H Firmware.

Know when Modicon M340 Bmx Noc 0401 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 5.0 MEDIUM
AV:N/AC:L/Au:N/C:N/I:N/A:P

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Confidentiality
None
Integrity
None
Availability
P

DescriptionCVE.org

The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny PLC control functions.

Threat Intelligence Overview

EPSS Score
0.7%
Top 27% exploitable
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.7%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

26
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +25
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.

Affected Products (CPE)CVE.org

cpe:2.3:o:schneider-electric:modicon_m340_bmx_noc_0401_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmx_noe_0100_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmx_noe_0100h_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmx_noe_0110_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmx_noe_0110h_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmx_nor_0200h_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2010_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2030_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy