Skip to main content

Rockwellautomation

Vendor security scorecard – 265 CVEs in the selected period

Period: 30d 90d 6m 1y All
Risk 1438
265
CVEs
44
Critical
176
High
2
KEV
21
PoC
207
Unpatched C/H
6.8%
Patch Rate
4.8%
Avg EPSS

Severity Breakdown

CRITICAL
44
HIGH
176
MEDIUM
40
LOW
5

Monthly CVE Trend

Top Risky CVEs

CVE Summary Severity CVSS EPSS Priority Signals
CVE-2023-20198 Cisco is providing an update for the ongoing investigation into observed exploitation of the web UI feature in Cisco IOS XE Software. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 10.0 99.6% 85
KEV PoC No patch
CVE-2020-12028 In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available. HIGH 8.1 51.0% 76
PoC No patch
CVE-2020-12029 All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available. HIGH 7.8 45.0% 74
PoC No patch
CVE-2018-14829 Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 16.1% 69
PoC No patch
CVE-2023-27855 In affected versions, a path traversal exists when processing a message in Rockwell Automation's ThinManager ThinServer. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available. CRITICAL 9.8 13.5% 69
PoC No patch
CVE-2023-2917 The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available. CRITICAL 9.8 67.8% 69
PoC No patch
CVE-2017-7924 An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. HIGH 7.5 10.0% 67
PoC No patch
CVE-2016-5645 Rockwell Automation MicroLogix 1400 PLC 1766-L32BWA, 1766-L32AWA, 1766-L32BXB, 1766-L32BWAA, 1766-L32AWAA, and 1766-L32BXBA devices have a hardcoded SNMP community, which makes it easier for remote. Rated high severity (CVSS 7.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Epss exploitation probability 30.3% and no vendor patch available. HIGH 7.3 30.3% 67
No patch
CVE-2023-2915 The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, Due to improper input validation, a path traversal vulnerability exists when the ThinManager. Rated critical severity (CVSS 9.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available. CRITICAL 9.1 78.1% 66
PoC No patch
CVE-2012-6437 The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Epss exploitation probability 11.8% and no vendor patch available. CRITICAL 9.8 11.8% 61
No patch
CVE-2018-19616 An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, no authentication required. Public exploit code available and no vendor patch available. HIGH 8.1 30.3% 60
PoC No patch
CVE-2018-10619 An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. Public exploit code available and no vendor patch available. HIGH 7.8 2.8% 59
PoC No patch
CVE-2018-14821 Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. HIGH 7.5 4.5% 58
PoC No patch
CVE-2020-6083 An exploitable denial of service vulnerability exists in the ENIP Request Path Port Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. HIGH 7.5 3.5% 58
PoC No patch
CVE-2020-6086 An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. HIGH 7.5 3.6% 58
PoC No patch

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy