Skip to main content

Abb

Vendor security scorecard – 11 CVEs in the selected period

Period: 30d 90d 6m 1y All
Risk 67
11
CVEs
1
Critical
8
High
0
KEV
0
PoC
9
Unpatched C/H
0.0%
Patch Rate
0.1%
Avg EPSS

Severity Breakdown

CRITICAL
1
HIGH
8
MEDIUM
2
LOW
0

Monthly CVE Trend

Top Risky CVEs

CVE Summary Severity CVSS EPSS Priority Signals
CVE-2025-13777 CVE-2025-13777 is an authentication bypass vulnerability in ABB AWIN Gateway devices (GW100 rev.2 and GW120) that allows attackers on adjacent networks to capture and replay authentication credentials without requiring privileges or user interaction. With a CVSS score of 8.3 and no evidence of active exploitation (not in KEV), this vulnerability enables attackers to gain unauthorized access and potentially compromise system confidentiality, integrity, and availability. HIGH 7.2 0.0% 46
No patch
CVE-2025-13779 Authentication bypass in ABB AWIN GW100 rev.2 (2.0-0, 2.0-1) and AWIN GW120 (1.2-0, 1.2-1) industrial gateways allows adjacent-network attackers to invoke critical functions without credentials, resulting in high confidentiality and availability impact. The flaw was reported by ABB itself and carries a CVSS 4.0 score of 7.2; no public exploit identified at time of analysis and EPSS sits at 0.03% (7th percentile), indicating low predicted exploitation likelihood despite the serious technical impact. HIGH 7.2 0.0% 46
No patch
CVE-2025-13778 Availability compromise of ABB AWIN GW100 rev.2 and AWIN GW120 industrial gateways stems from a missing authentication check on a critical function (CWE-306), enabling unauthenticated adjacent-network attackers to disrupt device operation. CVSS 4.0 scores the issue 7.1 with high availability impact but no confidentiality or integrity loss, and EPSS rates exploitation probability at just 0.03% (6th percentile) with no public exploit identified at time of analysis. HIGH 7.1 0.0% 46
No patch
CVE-2025-8754 Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.50 through 14. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available. HIGH 8.7 0.1% 44
No patch
CVE-2024-48842 Use of Hard-coded Credentials vulnerability in ABB FLXEON.3.5 and newer versions. Rated high severity (CVSS 7.3). No vendor patch available. HIGH 7.3 0.0% 37
No patch
CVE-2025-12143 Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.8.33. Rated medium severity (CVSS 6.9), this vulnerability is low attack complexity. No vendor patch available. MEDIUM 6.9 0.0% 34
No patch
CVE-2025-10205 Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.3.5. Rated high severity (CVSS 8.7), this vulnerability is no authentication required, low attack complexity. No vendor patch available. HIGH 8.7 0.0% –
No patch
CVE-2024-48851 Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.A remote code execution is possible due to an improper input validation.3.5. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available. HIGH 7.5 0.3% –
No patch
CVE-2025-10207 Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.3.5. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available. HIGH 7.5 0.1% –
No patch
CVE-2025-10504 Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.8.33. Rated medium severity (CVSS 6.9), this vulnerability is low attack complexity. No vendor patch available. MEDIUM 6.9 0.0% –
No patch
CVE-2025-10571 Authentication Bypass Using an Alternate Path or Channel vulnerability in ABB ABB Ability Edgenius.2.0.0, 3.2.1.1. Rated critical severity (CVSS 9.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available. CRITICAL 9.4 0.0% –
No patch

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy