Skip to main content

Scroll Medical Air Systems Firmware

3 CVEs product

Monthly

CVE-2018-7510 CRITICAL Act Now

In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Scroll Medical Air Systems Firmware
NVD
CVSS 3.0
9.8
EPSS
1.4%
CVE-2018-7526 HIGH This Week

In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Scroll Medical Air Systems Firmware
NVD
CVSS 3.0
7.5
EPSS
1.3%
CVE-2018-7518 CRITICAL Act Now

In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Scroll Medical Air Systems Firmware
NVD
CVSS 3.0
9.8
EPSS
1.3%
EPSS 1% CVSS 9.8
CRITICAL Act Now

In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Scroll Medical Air Systems Firmware
NVD
EPSS 1% CVSS 7.5
HIGH This Week

In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Scroll Medical Air Systems Firmware
NVD
EPSS 1% CVSS 9.8
CRITICAL Act Now

In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Scroll Medical Air Systems Firmware
NVD

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy