Modbus

5 CVEs product

Monthly

CVE-2025-55221 Dec 01, 16:15 HIGH This Week

Unauthenticated denial of service in Socomec DIRIS Digiware M-70 firmware 1.6.9 lets any host that can reach the device's Modbus TCP service crash or stall it by sending a single specially crafted packet to port 502; the same weakness affects the Modbus RTU over TCP USB function. The root cause is a missing-authentication condition (CWE-306) in a protocol that is unauthenticated by design, and the CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H, 7.5) confirms that no credentials or user interaction are needed and that only availability is impacted, with no disclosure or manipulation of data. No public exploit code and no confirmed active exploitation were identified at time of analysis, and the EPSS score is low at 0.06% (20th percentile), so realistic risk is bounded by exposure: the device is only at meaningful risk if port 502 is reachable from an attacker-controlled network rather than confined to a trusted OT/ICS segment.

Authentication Bypass Denial Of Service Modbus Diris M 70 Firmware
NVD VulDB
CVSS 3.1
7.5
EPSS
0.1%
CVE-2025-23417 Dec 01, 16:15 HIGH This Week

A single unauthenticated network packet sent to the Modbus RTU-over-TCP service of a Socomec DIRIS Digiware M-70 power-metering gateway running firmware 1.6.9 can crash the device, producing a denial-of-service condition (CVSS 3.1 base 7.5, AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). The root cause is a missing authentication check for a critical Modbus function (CWE-306), so no credentials and no user interaction are required; exploitability is bounded only by network reachability to the Modbus port, which on these OT/building-management devices is normally confined to segmented industrial networks rather than the public internet. No public exploit code has been identified, EPSS is very low (0.06%, 19th percentile), and there is no confirmed active exploitation (no CISA KEV listing) at the time of analysis. Impact is limited to availability - no data disclosure, integrity loss, or code execution has been demonstrated.

Authentication Bypass Denial Of Service Modbus Diris M 70 Firmware Ics
NVD VulDB
CVSS 3.1
7.5
EPSS
0.1%
CVE-2025-41704 Oct 14, 08:15 MEDIUM This Month

Unauthenticated remote attackers can cause a denial of service of the Modbus service on affected devices by sending a specific Modbus function code and sub-function code combination, with the description noting that core device functionality is unaffected. The issue is classified as CWE-770 (allocation of resources without limits or throttling), has a CVSS base score of 5.3 (availability impact only), and no public exploit code or active exploitation has been identified at time of analysis; EPSS is 1.59% (75th percentile).

Denial Of Service Modbus
NVD
CVSS 3.1
5.3
EPSS
1.6%
CVE-2025-41703 Oct 14, 08:15 HIGH This Week

Unauthenticated remote attackers with network reachability to a UPS's Modbus command interface can switch off the unit's power output, cutting power to downstream loads. Affected are UPS devices that expose output-control commands over Modbus/TCP (typically port 502) without requiring authentication (CWE-306); no credentials or user interaction are needed, so the realistic risk is concentrated on flat networks or management interfaces inadvertently exposed to untrusted segments. Impact is availability-only with no confidentiality or integrity loss, and no public exploit code or KEV entry was identified at time of analysis, while EPSS sits at 1.05% (64th percentile), reflecting a moderate-but-not-elevated likelihood of exploitation; CERT VDE advisory VDE-2025-072 and a Full Disclosure posting document the issue.

Authentication Bypass Denial Of Service Modbus
NVD
CVSS 3.1
7.5
EPSS
1.1%
CVE-2025-48466 Jun 24, 03:15 HIGH POC This Week

CVE-2025-48466 is a security vulnerability (CVSS 8.1). Risk factors: public PoC available.

Authentication Bypass IoT Modbus Wise 4010lan Firmware Wise 4050lan Firmware +2
NVD GitHub
CVSS 3.1
8.1
EPSS
0.1%
EPSS 0% CVSS 7.5
HIGH This Week

Unauthenticated denial of service in Socomec DIRIS Digiware M-70 firmware 1.6.9 lets any host that can reach the device's Modbus TCP service crash or stall it by sending a single specially crafted packet to port 502; the same weakness affects the Modbus RTU over TCP USB function. The root cause is a missing-authentication condition (CWE-306) in a protocol that is unauthenticated by design, and the CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H, 7.5) confirms that no credentials or user interaction are needed and that only availability is impacted, with no disclosure or manipulation of data. No public exploit code and no confirmed active exploitation were identified at time of analysis, and the EPSS score is low at 0.06% (20th percentile), so realistic risk is bounded by exposure: the device is only at meaningful risk if port 502 is reachable from an attacker-controlled network rather than confined to a trusted OT/ICS segment.

Authentication Bypass Denial Of Service Modbus +1
NVD VulDB
EPSS 0% CVSS 7.5
HIGH This Week

A single unauthenticated network packet sent to the Modbus RTU-over-TCP service of a Socomec DIRIS Digiware M-70 power-metering gateway running firmware 1.6.9 can crash the device, producing a denial-of-service condition (CVSS 3.1 base 7.5, AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). The root cause is a missing authentication check for a critical Modbus function (CWE-306), so no credentials and no user interaction are required; exploitability is bounded only by network reachability to the Modbus port, which on these OT/building-management devices is normally confined to segmented industrial networks rather than the public internet. No public exploit code has been identified, EPSS is very low (0.06%, 19th percentile), and there is no confirmed active exploitation (no CISA KEV listing) at the time of analysis. Impact is limited to availability - no data disclosure, integrity loss, or code execution has been demonstrated.

Authentication Bypass Denial Of Service Modbus +2
NVD VulDB
EPSS 2% CVSS 5.3
MEDIUM This Month

Unauthenticated remote attackers can cause a denial of service of the Modbus service on affected devices by sending a specific Modbus function code and sub-function code combination, with the description noting that core device functionality is unaffected. The issue is classified as CWE-770 (allocation of resources without limits or throttling), has a CVSS base score of 5.3 (availability impact only), and no public exploit code or active exploitation has been identified at time of analysis; EPSS is 1.59% (75th percentile).

Denial Of Service Modbus
NVD
EPSS 1% CVSS 7.5
HIGH This Week

Unauthenticated remote attackers with network reachability to a UPS's Modbus command interface can switch off the unit's power output, cutting power to downstream loads. Affected are UPS devices that expose output-control commands over Modbus/TCP (typically port 502) without requiring authentication (CWE-306); no credentials or user interaction are needed, so the realistic risk is concentrated on flat networks or management interfaces inadvertently exposed to untrusted segments. Impact is availability-only with no confidentiality or integrity loss, and no public exploit code or KEV entry was identified at time of analysis, while EPSS sits at 1.05% (64th percentile), reflecting a moderate-but-not-elevated likelihood of exploitation; CERT VDE advisory VDE-2025-072 and a Full Disclosure posting document the issue.

Authentication Bypass Denial Of Service Modbus
NVD
EPSS 0% CVSS 8.1
HIGH POC This Week

CVE-2025-48466 is a security vulnerability (CVSS 8.1). Risk factors: public PoC available.

Authentication Bypass IoT Modbus +4
NVD GitHub