Skip to main content

Mitsubishi Electric Corporation

5 CVEs vendor

Monthly

CVE-2026-8806 Jun 19, 02:31 HIGH CISA Act Now

Denial-of-service in Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Modules (all versions) allows unauthenticated remote attackers to halt the module's communication function by flooding its Ethernet port with packets. The high packet rate overwhelms internal anomaly-detection processing and stops communications - a critical impact for the industrial control environments these PLCs operate in. No public exploit identified at time of analysis, but the CVSS 4.0 score of 8.7 reflects high availability impact in operational technology contexts.

Information Disclosure Mitsubishi Electric Melsec Iq F Series Fx5 Enet Ip Ethernet Module Fx5 Enet Ip Mitsubishi Electric Corporation
NVD
CVSS 4.0
8.7
EPSS
0.4%
CVE-2026-8805 Jun 19, 02:26 HIGH CISA Act Now

Denial-of-service in Mitsubishi Electric MELSEC iQ-F Series FX5-EIP EtherNet/IP module (versions 1.000 and prior) allows a remote unauthenticated attacker to crash the device by rapidly opening many TCP connections, which trips an integer overflow in the EtherNet/IP connection-management logic and triggers improper memory access. No public exploit identified at time of analysis, but the CVSS 4.0 vector (AV:N/AC:L/PR:N/UI:N) and high availability impact make this a meaningful operational-technology (OT) concern for plants relying on the affected PLC module. Reported by the vendor and tracked in vendor PSIRT advisory 2026-002, JVN VU#97140216, and CISA ICS advisory ICSA-26-169-05.

Buffer Overflow Integer Overflow Mitsubishi Electric Melsec Iq F Series Fx5 Eip Ethernet Ip Module Fx5 Eip Mitsubishi Electric Corporation
NVD
CVSS 4.0
8.7
EPSS
0.4%
CVE-2026-5667 Jun 17, 10:53 HIGH This Week

Unauthenticated adjacent-network access to a wide range of Mitsubishi Electric Wi-Fi-enabled appliances - including room air conditioners (for Japan and abroad), wireless LAN adapters for room/packaged air conditioners, refrigerators, heat-pump water heaters, bathroom dryer/heater/ventilation units, Lossnay ventilation systems, IH cooking heaters, and rice cookers - is possible via a hard-coded SSID and password embedded in the products' Wi-Fi access-point mode. An attacker within Wi-Fi radio range can read device telemetry (operation status, set/room temperature), alter air-conditioner or Wi-Fi settings, or push the Wi-Fi interface into a denial-of-service state. No public exploit is identified at time of analysis (EPSS 0.15%, percentile 5%; CISA SSVC Exploitation: none) and the issue is not in CISA KEV, but the credentials are static across the product line, making opportunistic abuse trivial once they are leaked or recovered from firmware.

Authentication Bypass Room Air Conditioners For Japan Msz Bkr2223 W Room Air Conditioners For Japan Msz Bkr2224 W Room Air Conditioners For Japan Msz Bkr2523 W Room Air Conditioners For Japan Msz Bkr2524 W +2477
NVD VulDB
CVSS 4.0
7.2
EPSS
0.2%
CVE-2025-14816 Apr 08, 13:23 CRITICAL CISA Emergency

SQL Server credentials are displayed in cleartext within the Hyper Historian Splitter GUI across multiple Mitsubishi Electric SCADA/HMI platforms (GENESIS64, ICONICS Suite, MC Works64, and related products), allowing local authenticated attackers with low privileges to capture database credentials and subsequently gain unauthorized access to backend SQL Servers. This affects versions 10.97.3 and prior for most products and all versions of MC Works64. No active exploitation confirmed (not in CISA KEV), though CISA has issued ICS advisory ICSA-26-097-01. With a CVSS 9.3 (Critical) score reflecting high confidentiality, integrity, and availability impact on both vulnerable and subsequent systems, the risk centers on credential theft enabling downstream SQL Server compromise.

Information Disclosure Genesis64 Iconics Suite Mobilehmi Hyper Historian +4
NVD
CVSS 4.0
9.3
EPSS
0.0%
CVE-2025-14815 Apr 08, 13:15 CRITICAL CISA Emergency

Plaintext SQL Server credential storage in Mitsubishi Electric SCADA/HMI products allows local authenticated attackers with low-complexity exploitation to extract database credentials from SQLite cache files, enabling subsequent unauthorized SQL Server access for data manipulation and denial-of-service attacks. Affects multiple product lines including GENESIS64 ≤10.97.3, ICONICS Suite ≤10.97.3, and all MC Works64 versions when local SQLite caching is enabled with SQL authentication. CVSS 9.3 severity reflects extensive downstream impact potential (confidentiality, integrity, availability across both vulnerable system and connected SQL Server). No evidence of active exploitation (not in CISA KEV), but EPSS data unavailable and attack complexity rated low with only local authenticated access required.

Information Disclosure Genesis64 Iconics Suite Mobilehmi Hyper Historian +4
NVD
CVSS 4.0
9.3
EPSS
0.0%
EPSS 0% CVSS 8.7
HIGH Act Now

Denial-of-service in Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Modules (all versions) allows unauthenticated remote attackers to halt the module's communication function by flooding its Ethernet port with packets. The high packet rate overwhelms internal anomaly-detection processing and stops communications - a critical impact for the industrial control environments these PLCs operate in. No public exploit identified at time of analysis, but the CVSS 4.0 score of 8.7 reflects high availability impact in operational technology contexts.

Information Disclosure Mitsubishi Electric Melsec Iq F Series Fx5 Enet Ip Ethernet Module Fx5 Enet Ip Mitsubishi Electric Corporation
NVD
EPSS 0% CVSS 8.7
HIGH Act Now

Denial-of-service in Mitsubishi Electric MELSEC iQ-F Series FX5-EIP EtherNet/IP module (versions 1.000 and prior) allows a remote unauthenticated attacker to crash the device by rapidly opening many TCP connections, which trips an integer overflow in the EtherNet/IP connection-management logic and triggers improper memory access. No public exploit identified at time of analysis, but the CVSS 4.0 vector (AV:N/AC:L/PR:N/UI:N) and high availability impact make this a meaningful operational-technology (OT) concern for plants relying on the affected PLC module. Reported by the vendor and tracked in vendor PSIRT advisory 2026-002, JVN VU#97140216, and CISA ICS advisory ICSA-26-169-05.

Buffer Overflow Integer Overflow Mitsubishi Electric Melsec Iq F Series Fx5 Eip Ethernet Ip Module Fx5 Eip +1
NVD
EPSS 0% CVSS 7.2
HIGH This Week

Unauthenticated adjacent-network access to a wide range of Mitsubishi Electric Wi-Fi-enabled appliances - including room air conditioners (for Japan and abroad), wireless LAN adapters for room/packaged air conditioners, refrigerators, heat-pump water heaters, bathroom dryer/heater/ventilation units, Lossnay ventilation systems, IH cooking heaters, and rice cookers - is possible via a hard-coded SSID and password embedded in the products' Wi-Fi access-point mode. An attacker within Wi-Fi radio range can read device telemetry (operation status, set/room temperature), alter air-conditioner or Wi-Fi settings, or push the Wi-Fi interface into a denial-of-service state. No public exploit is identified at time of analysis (EPSS 0.15%, percentile 5%; CISA SSVC Exploitation: none) and the issue is not in CISA KEV, but the credentials are static across the product line, making opportunistic abuse trivial once they are leaked or recovered from firmware.

Authentication Bypass Room Air Conditioners For Japan Msz Bkr2223 W Room Air Conditioners For Japan Msz Bkr2224 W +2479
NVD VulDB
EPSS 0% CVSS 9.3
CRITICAL Emergency

SQL Server credentials are displayed in cleartext within the Hyper Historian Splitter GUI across multiple Mitsubishi Electric SCADA/HMI platforms (GENESIS64, ICONICS Suite, MC Works64, and related products), allowing local authenticated attackers with low privileges to capture database credentials and subsequently gain unauthorized access to backend SQL Servers. This affects versions 10.97.3 and prior for most products and all versions of MC Works64. No active exploitation confirmed (not in CISA KEV), though CISA has issued ICS advisory ICSA-26-097-01. With a CVSS 9.3 (Critical) score reflecting high confidentiality, integrity, and availability impact on both vulnerable and subsequent systems, the risk centers on credential theft enabling downstream SQL Server compromise.

Information Disclosure Genesis64 Iconics Suite +6
NVD
EPSS 0% CVSS 9.3
CRITICAL Emergency

Plaintext SQL Server credential storage in Mitsubishi Electric SCADA/HMI products allows local authenticated attackers with low-complexity exploitation to extract database credentials from SQLite cache files, enabling subsequent unauthorized SQL Server access for data manipulation and denial-of-service attacks. Affects multiple product lines including GENESIS64 ≤10.97.3, ICONICS Suite ≤10.97.3, and all MC Works64 versions when local SQLite caching is enabled with SQL authentication. CVSS 9.3 severity reflects extensive downstream impact potential (confidentiality, integrity, availability across both vulnerable system and connected SQL Server). No evidence of active exploitation (not in CISA KEV), but EPSS data unavailable and attack complexity rated low with only local authenticated access required.

Information Disclosure Genesis64 Iconics Suite +6
NVD

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy