Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain local low-priv code execution
-
DeliveryOpen BS_HWMIO64_W10 driver device handle
-
ExploitSend crafted IOCTL with attacker PhysicalAddress
-
ExecutionTrigger write-what-where in sub_1105C
-
PersistOverwrite kernel token/callback structure
-
ImpactEscalate to SYSTEM
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Write-what-where prevention
|
| Exploitation Conditions | Requires local access to a Windows host on which the BioStar Temperature Monitor Utility 1.2.1806.2200 (and its BS_HWMIO64_W10.sys driver) is installed and loaded; the attacker must already have low-privilege code execution (PR:L) able to open the driver's device object and issue the IOCTL handled by sub_1105C with a controlled PhysicalAddress. No user interaction and no non-default configuration are needed once the driver is present. Limiting factors: exploitation is local-only (not remotely reachable), depends on the vulnerable signed driver being loaded, and the product's small deployment base narrows real-world exposure - though the driver could be abused BYOVD-style on machines that never installed the full utility. |
| Impact | This is a genuine local privilege-escalation priority, not a high-CVSS-but-low-risk paper cut. The vulnerability is a classic write-what-where primitive (CWE-123) exposed through an IOCTL handler (sub_1105C) in the kernel-mode driver BS_HWMIO64_W10.sys, where the attacker-controlled PhysicalAddress argument lets an unprivileged local user write arbitrary data to arbitrary kernel/physical memory - the canonical building block for escalating to SYSTEM. The CVSS 4.0 vector (AV:L/AC:L/AT:N/PR:L/UI:N) confirms local access with only low privileges and no user interaction, which is realistic for any logged-in or malware-dropped user. Exploitation status: publicly available exploit code exists (E:P and 'exploit has been disclosed publicly'), but there is NO CISA KEV listing and NO EPSS score provided, so this is proof-of-concept availability, not confirmed active exploitation - the two must not be conflated. The vendor-assigned 9.3 is inflated by the subsequent-system impact metrics (SC:H/SI:H/SA:H); a local kernel LPE compromises the same host, so those subsequent-system 'H' values are questionable and I would score subsequent impact as N, yielding roughly 8.5 (4.0) / 7.8 (3.1). Net: a real, reliably-exploitable local-to-SYSTEM issue mitigated only by the local-access requirement and the niche product footprint. Note the tag mismatch - labeled 'Information Disclosure' but this is a kernel WRITE primitive (privilege escalation / memory corruption), not a read/disclosure bug. |
| Exploit ScenarioDerived | A low-privileged local user (or malware already running as a standard user) opens a handle to the BS_HWMIO64_W10 driver device and issues the vulnerable IOCTL with a crafted PhysicalAddress, using the write-what-where primitive to overwrite a kernel structure (e.g. a token privilege field or callback pointer) and elevate to SYSTEM. Public exploit code has been disclosed, lowering the bar to weaponization; because the vulnerable signed driver can be dropped and loaded independently, it is also a candidate for bring-your-own-vulnerable-driver (BYOVD) abuse on systems that never installed the utility. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Sep 21, 2026
Local privilege escalation in the BioStar Temperature Monitor Utility (1.2.1806.2200, all versions flagged by CPE) lets a low-privileged process on an affected Windows host write attacker-controlled data to an arbitrary physical address through the bundled BS_HWMIO64_W10.sys kernel driver, escalating to SYSTEM and gaining full control of the machine. According to the assessed CVSS 3.1 vector (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H), exploitation requires local low-privilege code execution able to open the driver's device object and send the crafted IOCTL, with no user interaction and no non-default configuration once the signed driver is loaded. Publicly available exploit code exists (the CVSS 4.0 vector carries E:P and the disclosure states the exploit was released publicly), but there is no indication of confirmed active exploitation in the wild and no CISA KEV listing; the vendor was contacted and did not respond, so no vendor patch was identified at time of analysis.
RemediationAI
No vendor-released patch was identified at time of analysis: BioStar was contacted early about the issue and did not respond, so there is no fixed version to upgrade to and no vendor advisory beyond the VulDB records (https://vuldb.com/vuln/408057, https://vuldb.com/cve/CVE-2026-94142). The most direct action is to uninstall the BioStar Temperature Monitor Utility from hosts that do not require it, which removes the driver entirely and eliminates the attack surface - the trade-off being loss of temperature and hardware-sensor monitoring. Where the utility must be kept, prevent the driver from loading or from being reachable by untrusted callers: enforce Windows Defender Application Control or AppLocker with Microsoft's vulnerable driver blocklist/HVCI policy, or a hash-based block rule targeting BS_HWMIO64_W10.sys, accepting that this disables the monitoring functionality and may need updates if the vendor ships a new driver build; alternatively, stop and disable the associated kernel service and tighten the driver's device-object ACL (via an OEM-defined ACL or an ACL-modifying filter driver) so only fully trusted admin processes can open it, at the cost of breaking sensor reads for non-admin users and the risk that service repair/reinstall re-enables the driver. Also hunt for BYOVD abuse of this signed driver on hosts that never installed the utility, and treat any local process opening the driver's device object as suspicious. Because a public exploit exists, prioritize these compensating controls on systems where the utility is present until a vendor fix appears.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The root cause is CWE-123 (Write-what-where condition) in BioStar's Temperature Monitor Utility, a Windows hardware-monitoring application for reading motherboard sensors such as temperatures, voltages, and fan speeds. The vulnerable component is the 64-bit kernel-mode driver BS_HWMIO64_W10.sys, whose IOCTL handler function sub_1105C accepts a caller-supplied PhysicalAddress argument and uses it to address physical memory or memory-mapped hardware I/O without validating that the address falls within a permitted range. Because the resulting write occurs at ring 0 with attacker-influenced address and data, a local process that can open the driver's device object and issue the IOCTL obtains a kernel arbitrary-write primitive, which can be leveraged to overwrite kernel structures, disable or bypass security controls, and elevate to SYSTEM. CPE data (cpe:2.3:a:biostar:temperature_monitor_utility:*:*:*:*:*:*:*:*) indicates the affected product line as a whole, with 1.2.1806.2200 the confirmed vulnerable build. Notably, the abusable component is a signed kernel driver, which means it can also be dropped and loaded directly on hosts where the full utility was never installed, enabling bring-your-own-vulnerable-driver (BYOVD) abuse, though the limiting factors remain that exploitation is strictly local and the utility's deployment base is small.
Know when Temperature Monitor Utility gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P
Local IOCTL reachable by a low-priv user (AV:L/PR:L/AC:L, no UI); kernel write-what-where yields full SYSTEM compromise (C/I/A:H) but stays on the same host, so S:U.
Primary rating from Vendor (VulDB).
CVSS VectorVendor: VulDB
Lifecycle Timeline
3DescriptionCVE.org
A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200. Affected by this vulnerability is the function sub_1105C of the file BS_HWMIO64_W10.sys of the component IOCTL Handler. Such manipulation of the argument PhysicalAddress leads to write-what-where condition. The attack needs to be performed locally. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Articles & Coverage 1
Technical POC Analysis
No patch diff is present in the supplied evidence, and the advisory summary states no vendor patch was identified (vendor contacted, no response).
Full technical POC analysis - root cause, step-by-step exploitation and patch breakdown - is part of the Pro and Business plans.
Latest POC
1 PoC candidate from github (unverified)
Sign in to open the public PoC links collected for this CVE.
Executive ViewAI
Organizations running the BioStar Temperature Monitor Utility 1.2.1806.2200 on Windows endpoints are exposed to a local privilege-escalation flaw in its bundled BS_HWMIO64_W10.sys kernel driver. A low-privileged local user can leverage publicly available exploit code to gain SYSTEM-level control of an affected host, creating risk of credential theft, tampering, and lateral movement. Because no vendor patch is available and the vendor has not responded, leadership should treat remediation as an urgent containment and inventory exercise.
No vendor patch is available. Interim mitigations: remove or disable BioStar Temperature Monitor Utility 1.2.1806.2200, block BS_HWMIO64_W10.sys via WDAC/AppLocker or driver blocklist, enforce least privilege and restrict local logon, and monitor for driver load and crafted IOCTL activity.