Skip to main content

SolarView Compact EUVDEUVD-2026-77250

| CVE-2026-82794 HIGH
OS Command Injection (CWE-78)
2026-09-14 jpcert GHSA-66xm-m3f9-w5fh
8.7
CVSS 4.0 · Vendor: jpcert
Share

Severity by source

Vendor (jpcert) PRIMARY
8.7 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
8.8 HIGH

Network-exploitable command injection requiring only a valid login (PR:L); impact confined to the device with no scope change.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (jpcert).

CVSS VectorVendor: jpcert

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

4
Patch available
Sep 14, 2026 - 08:01 EUVD
Analysis Generated
Sep 14, 2026 - 07:25 vuln.today
CVSS changed
Sep 14, 2026 - 07:22 NVD
8.8 (HIGH) 8.7 (HIGH)
CVE Published
Sep 14, 2026 - 06:46 cve.org
HIGH 8.7

DescriptionCVE.org

SolarView Compact contains an OS command Injection vulnerability in in Schedule Settings. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.

AnalysisAI

OS command injection in Contec SolarView Compact (models SV-CPT-MC310 and SV-CPT-MC310F) allows any authenticated low-privilege user to execute arbitrary operating system commands through the Schedule Settings feature. Successful exploitation grants full control over the underlying device with high impact to confidentiality, integrity, and availability. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Persist
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires the attacker to authenticate to the SolarView Compact web management interface with at least low-privilege credentials (PR:L confirmed by CVSS 4.0 vector). … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 4.0 score of 8.7 with vector AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H correctly characterizes this as a severe, network-exploitable vulnerability requiring no special preconditions beyond valid credentials, with full device compromise as the outcome. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Apply the firmware update for SolarView Compact as documented in the Contec security advisory (https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_sv_26091000_en.pdf) and the JVN disclosure (https://jvn.jp/en/vu/JVNVU97753461/). … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours, audit and restrict Schedule Settings access on all affected SolarView Compact devices to administrative accounts only, and enable comprehensive logging of all Schedule Settings modifications. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.