Severity by source
CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary rating from Vendor (Rockwell) · only source for this CVE.
CVSS VectorVendor: Rockwell
CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Lifecycle Timeline
2DescriptionCVE.org
A security issue exists within FactoryTalk® Services Platform (FTSP), allowing an attacker to bypass JWT signature validation during Okta Web Authentication. The vulnerability stems from the application not verifying that the JWT algorithm is configured for RSA, enabling an attacker to set the algorithm to "none" and craft forged tokens. This could allow an authenticated low-privilege user to impersonate any authorized user on the FTSP server, resulting in unauthorized access to system configuration and the ability to grant permissions to other systems protected by FTSP.
AnalysisAI
Authentication bypass in Rockwell Automation FactoryTalk Services Platform (FTSP) lets an authenticated low-privilege user forge JWT tokens during Okta Web Authentication because the application fails to enforce the RSA signing algorithm, permitting the classic 'alg:none' attack. A successful attacker can impersonate any authorized user, reaching system configuration and granting permissions to other systems that FTSP protects. …
Unlock full vulnerability intelligence
- Risk assessment & exploitation conditions
- Attack chain visualization
- Remediation with exact patch versions
- Threat intelligence from 22 sources
- Personal watchlist & email alerts
Free forever · No credit card required
Recommended ActionAI
Within 24 hours, inventory all FTSP deployments and identify those using Okta Web Authentication; restrict administrative access through network controls and review authentication logs for suspicious token issuance or privilege escalation attempts. …
Sign in for detailed remediation steps and compensating controls.
Threat intelligence, references, and detailed analysis are available after sign-in.
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platfor
A vulnerability exists in Rockwell Automation FactoryTalk® Service Platform that allows a malicious user to obtain the s
A privilege escalation vulnerability exists in Rockwell Automation FactoryTalk® Service Platform (FTSP). Rated high seve
In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service (RdcyHost.exe) does not
Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user
Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-
Integer signedness error in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR
Untrusted search path vulnerability in the Clean Utility application in Rockwell Automation FactoryTalk Services Platfor
Same weakness CWE-1390 – Weak Authentication
View allSame technique Authentication Bypass
View allShare
External POC / Exploit Code
Leaving vuln.today