Skip to main content

Unifi Play Poweramp EUVDEUVD-2026-22093

| CVE-2026-22564 CRITICAL
Improper Access Control (CWE-284)
2026-04-13 hackerone GHSA-h9r9-rwmc-3wm5
9.8
CVSS 3.1 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Recon
    Gain network access to management VLAN
  2. Delivery
    Send unauthenticated API request to enable SSH
  3. Exploit
    Authenticate to SSH service
  4. Install
    Execute commands as root
  5. C2
    Modify system configuration
  6. Execute
    Establish persistence mechanism
  7. Impact
    Achieve complete device compromise

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Access control enforcement
MITRE ATT&CK

1 technique across 1 tactic: Defense Evasion

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Network access to the UniFi Play device management interface on TCP ports 80/443 or the device's proprietary management port. The vulnerability specifically affects the SSH enablement functionality accessible through the web management interface. Exploitation succeeds against default configurations of UniFi Play PowerAmp (≤1.0.35) and UniFi Play Audio Port (≤1.0.24) without requiring valid administrator credentials, special feature enablement, or non-standard deployment modes. Devices isolated to properly segmented management VLANs with restricted firewall policies would not be accessible to remote internet-based attackers but remain vulnerable to insider threats or attackers with existing network presence.

Impact

The CVSS 9.8 Critical rating reflects maximum theoretical impact (network-accessible, unauthenticated, affects all CIA triad elements), but real-world risk indicators paint a more nuanced picture. EPSS probability of 0.01% (3rd percentile) suggests security researchers and threat actors have shown minimal exploitation interest in the three weeks since disclosure. No confirmed active exploitation exists (not listed in CISA KEV), and no public proof-of-concept code has been identified. The SSVC decision framework would classify this as 'Attend' rather than 'Act Immediately': exploitation is possible but not demonstrated (PoE: none), the attack cannot be reliably automated at scale given the requirement to identify specific Ubiquiti audio devices on target networks, and technical impact is total system compromise. Primary risk exists in environments where UniFi Play devices are directly exposed to untrusted networks (internet-facing management interfaces, guest networks) rather than properly segmented audio VLANs. Organizations following network segmentation best practices face significantly reduced exposure, as the attacker requires existing network access to the management plane. The 'Authentication Bypass' tag confirms this is a true pre-auth vulnerability, elevating priority for internet-exposed deployments.

Exploit ScenarioDerived

An attacker on the same network as UniFi Play devices (corporate LAN, guest Wi-Fi, or internet if devices have public IPs) sends crafted HTTP/HTTPS requests to the device management interface to enable the SSH service without providing valid credentials. Once SSH is activated, the attacker establishes an SSH session using default, weak, or brute-forced credentials, gaining root shell access. From this position, the attacker modifies system configurations, implants persistent backdoors, intercepts audio streams, pivots to other network segments, or disrupts audio operations across the commercial installation.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Apr 15, 2026

Remote unauthenticated attackers can enable SSH and gain complete system control on Ubiquiti UniFi Play PowerAmp (≤1.0.35) and UniFi Play Audio Port (≤1.0.24) devices via improper access control. The vulnerability bypasses authentication mechanisms, allowing network-accessible adversaries to modify system configurations with critical impact across confidentiality, integrity, and availability (CVSS 9.8). No public exploit identified at time of analysis, with low EPSS probability (0.01%, 3rd percentile) suggesting limited observed exploitation attempts despite the critical severity rating.

RemediationAI

Immediately update UniFi Play PowerAmp devices to version 1.0.38 or later and UniFi Play Audio Port devices to version 1.1.9 or later, as specified in Ubiquiti Security Advisory Bulletin 063 (https://community.ui.com/releases/Security-Advisory-Bulletin-063/e468dd4b-5090-4ef8-89d8-939903c08e83). Patches are vendor-released and address the improper access control flaw. Until patching is complete, implement compensating controls including isolating UniFi Play devices to dedicated management VLANs with firewall restrictions permitting only authorized administrator source IP addresses, disabling remote management access if not operationally required, and monitoring device logs for unexpected SSH enablement or authentication attempts. Review existing device configurations to verify SSH has not been maliciously enabled on unpatched systems. Organizations using UniFi Network Controller or cloud-based management should verify automatic firmware updates are enabled to receive future security patches.

Affected VersionsENISA

UniFi Play PowerAmp 0 <1.0.38
UniFi Play Audio Port 0 <1.1.9

Affected Packages

euvd unifi_play_audio_port fix: 1.1.9
euvd unifi_play_poweramp fix: 1.0.38

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 2 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability affects Ubiquiti's UniFi Play audio management ecosystem, specifically the PowerAmp and Audio Port devices designed for commercial audio distribution over IP networks. The issue stems from CWE-284 (Improper Access Control), a broad category indicating insufficient enforcement of access restrictions. The vulnerability manifests in the SSH service management interface, where authorization checks fail to prevent unauthorized callers from toggling SSH daemon state. The affected products run embedded Linux firmware with network-accessible management interfaces. CPE identifiers cpe:2.3:a:ubiquiti_inc:unifi_play_poweramp and cpe:2.3:a:ubiquiti_inc:unifi_play_audio_port confirm the scope. The CVSS vector AV:N indicates exploitation via standard network protocols without requiring local or adjacent network access, while AC:L confirms no mitigating complexity factors like race conditions or cryptographic challenges. The vulnerability was responsibly disclosed through HackerOne's bug bounty program before public disclosure.

Know when Unifi Play Poweramp gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

4
Patch released
Apr 30, 2026 - 16:14 nvd
Patch available
Analysis Updated
Apr 16, 2026 - 05:44 EUVD-patch-fix
executive summary
Patch available
Apr 16, 2026 - 05:29 EUVD
1.0.38,1.1.9
CVE Published
Apr 13, 2026 - 21:28 nvd
CRITICAL 9.8

DescriptionCVE.org

An Improper Access Control vulnerability could allow a malicious actor with access to the UniFi Play network to enable SSH to make unauthorized changes to the system.

Affected Products: UniFi Play PowerAmp (Version 1.0.35 and earlier) UniFi Play Audio Port  (Version 1.0.24 and earlier)

Mitigation: Update UniFi Play PowerAmp to Version 1.0.38 or later Update UniFi Play Audio Port  to Version 1.1.9 or later

Executive ViewAI

Why It Matters

Ubiquiti UniFi Play PowerAmp and Audio Port devices contain a critical remote authentication bypass (CVE-2026-22564) that allows unauthenticated network attackers to enable SSH and assume complete system control. Organizations deploying these devices in networked audio infrastructure face immediate risk of unauthorized access, data compromise, and service disruption without remediation.

Business Impact: Severe
Compensating Controls

Apply vendor patch. If patch cannot be immediately deployed: (1) restrict network access to affected devices via firewall ACLs-permit only from trusted administrative IP ranges; (2) disable SSH access at the application level if accessible through management interface; (3) implement continuous network monitoring for SSH connection attempts to these devices; (4) segment audio infrastructure on isolated VLAN with limited east-west traffic.

Threat Intelligence Overview

EPSS Score
0.0%
Top 97% exploitable
Social Media
1
Sightings
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.0%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Out-of-Cycle
Exploitation
None
System Exposure· derived
Open
Automatable
Yes
Human Impact
Very High
Technical Impact
Total

Priority Score

49
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +49
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy