Skip to main content

Ubiquiti CVE-2026-22566

| EUVDEUVD-2026-22095 HIGH
Improper Access Control (CWE-284)
2026-04-13 hackerone GHSA-qg4j-p3wp-3c25
7.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

9
Patch released
Apr 30, 2026 - 16:14 nvd
Patch available
Re-analysis Queued
Apr 17, 2026 - 15:37 vuln.today
cvss_changed
Analysis Updated
Apr 16, 2026 - 05:57 EUVD-patch-fix
executive_summary
Re-analysis Queued
Apr 16, 2026 - 05:29 backfill_euvd_patch
patch_released
Patch available
Apr 16, 2026 - 05:29 EUVD
1.0.38,1.1.9
Analysis Generated
Apr 15, 2026 - 12:36 vuln.today
EUVD ID Assigned
Apr 13, 2026 - 21:45 euvd
EUVD-2026-22095
Analysis Generated
Apr 13, 2026 - 21:45 vuln.today
CVE Published
Apr 13, 2026 - 21:28 nvd
HIGH 7.5

DescriptionCVE.org

An Improper Access Control vulnerability could allow a malicious actor with access to the UniFi Play network to obtain UniFi Play WiFi credentials.

Affected Products: UniFi Play PowerAmp (Version 1.0.35 and earlier) UniFi Play Audio Port  (Version 1.0.24 and earlier)

Mitigation: Update UniFi Play PowerAmp to Version 1.0.38 or later Update UniFi Play Audio Port  to Version 1.1.9 or later

AnalysisAI

Improper access control in Ubiquiti UniFi Play PowerAmp (≤1.0.35) and Audio Port (≤1.0.24) exposes WiFi credentials to network-adjacent attackers without authentication. The CVSS:3.1 vector (AV:N/AC:L/PR:N/UI:N) indicates remote exploitation with no authentication required, though the vulnerability description specifies 'access to the UniFi Play network' as a prerequisite. Reported via HackerOne bug bounty. EPSS score of 0.01% (1st percentile) suggests minimal observed exploitation activity, and no public exploit code or CISA KEV listing identified at time of analysis.

Technical ContextAI

This vulnerability affects Ubiquiti's UniFi Play audio streaming ecosystem, specifically the PowerAmp (hardware amplifier) and Audio Port (network audio adapter) products. The flaw is classified as CWE-284 (Improper Access Control), indicating insufficient enforcement of access restrictions to sensitive WiFi credential data. The affected CPE strings (cpe:2.3:a:ubiquiti_inc:unifi_play_poweramp and cpe:2.3:a:ubiquiti_inc:unifi_play_audio_port) confirm these are network-connected audio devices that rely on WiFi credentials for connectivity. The access control failure likely exists in the device's web management interface, API endpoints, or network service protocols that should authenticate and authorize requests before disclosing credentials. The CVSS confidentiality impact is High (C:H) with no integrity or availability impact, consistent with credential disclosure without system modification capabilities.

RemediationAI

Upgrade UniFi Play PowerAmp to version 1.0.38 or later and UniFi Play Audio Port to version 1.1.9 or later to remediate this vulnerability. Patches are available through Ubiquiti's standard firmware update mechanisms accessible via the UniFi management interface or device web UI. Consult Ubiquiti Security Advisory Bulletin 063 at https://community.ui.com/releases/Security-Advisory-Bulletin-063/e468dd4b-5090-4ef8-89d8-939903c08e83 for detailed update instructions. As an interim mitigation measure, isolate UniFi Play devices on dedicated management VLANs with strict access control lists, implement network segmentation to prevent unauthorized access to the UniFi Play network segment, and rotate WiFi credentials post-patching if unauthorized access is suspected. Organizations should audit which devices have network access to UniFi Play equipment and restrict to authorized management stations only.

CVE-2026-34910 CRITICAL POC
10.0 May 22

Unauthenticated command injection in Ubiquiti UniFi OS devices allows remote attackers with network access to execute ar

CVE-2026-34909 CRITICAL POC
10.0 May 22

Path traversal in Ubiquiti UniFi OS devices allows network-adjacent attackers to read sensitive files from the underlyin

CVE-2026-34908 CRITICAL POC
10.0 May 22

Unauthorized system modification on Ubiquiti UniFi OS devices allows network-adjacent attackers to alter device configur

CVE-2013-1606 HIGH POC
7.5 Jul 18

Buffer overflow in the ubnt-streamer RTSP service on the Ubiquiti UBNT AirCam with airVision firmware before 1.1.6 allow

CVE-2026-22557 CRITICAL POC
10.0 Mar 19

A critical path traversal vulnerability exists in the UniFi Network Application that allows unauthenticated remote attac

CVE-2023-1458 CRITICAL POC
9.8 Mar 25

A vulnerability has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6 and classified as critical. Rated critical severi

CVE-2023-24104 CRITICAL POC
9.8 Feb 23

Ubiquiti Networks UniFi Dream Machine Pro v7.2.95 allows attackers to bypass domain restrictions via crafted packets. Ra

CVE-2016-7792 HIGH POC
8.8 Jan 23

Ubiquiti Networks UniFi 5.2.7 does not restrict access to the database, which allows remote attackers to modify the data

CVE-2023-23912 HIGH POC
8.8 Feb 09

A vulnerability, found in EdgeRouters Version 2.0.9-hotfix.5 and earlier and UniFi Security Gateways (USG) Version 4.4.5

CVE-2023-2375 HIGH POC
7.3 Apr 28

A weakness has been identified in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. Rated high severity (CVSS 7.3), this vulne

CVE-2023-2374 HIGH POC
7.3 Apr 28

A security flaw has been discovered in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. Rated high severity (CVSS 7.3), this

CVE-2023-2378 HIGH POC
7.3 Apr 28

A flaw has been found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. Rated high severity (CVSS 7.3), this vulnerability

Share

CVE-2026-22566 vulnerability details – vuln.today