Skip to main content

Tenda EUVDEUVD-2026-16472

| CVE-2026-4903 HIGH
Stack-based Buffer Overflow (CWE-121)
2026-03-26 VulDB
7.4
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

4
PoC Detected
Mar 31, 2026 - 21:08 vuln.today
Public exploit code
EUVD ID Assigned
Mar 26, 2026 - 23:01 euvd
EUVD-2026-16472
Analysis Generated
Mar 26, 2026 - 23:01 vuln.today
CVE Published
Mar 26, 2026 - 22:30 nvd
HIGH 7.4

DescriptionCVE.org

A flaw has been found in Tenda AC5 15.03.06.47. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. This manipulation of the argument PPPOEPassword causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used.

AnalysisAI

Remote attackers with low-level credentials can execute arbitrary code on Tenda AC5 wireless routers running firmware version 15.03.06.47 by exploiting a stack-based buffer overflow in the formQuickIndex function via a crafted PPPOEPassword parameter in POST requests to /goform/QuickIndex. Publicly available exploit code exists, including detailed proof-of-concept documentation published on Notion, elevating immediate risk for devices exposed to authenticated network users. The CVSS score of 8.8 reflects high impact across confidentiality, integrity, and availability with network-based attack vector and low complexity.

Technical ContextAI

The vulnerability resides in the formQuickIndex function within the POST request handler at the /goform/QuickIndex endpoint of Tenda AC5 router firmware 15.03.06.47 (CPE: cpe:2.3:a:tenda:ac5:*:*:*:*:*:*:*:*). The root cause is CWE-121, a stack-based buffer overflow occurring when the application fails to validate the length of the PPPOEPassword argument before copying it to a fixed-size stack buffer. This classic memory corruption vulnerability allows attackers to overwrite adjacent memory regions, including the function return address, enabling control of program execution flow. The /goform/ path typically handles router configuration and management functions, where sensitive operations like PPPoE authentication credential management are processed.

RemediationAI

No vendor-released patch identified at time of analysis based on available reference data. Until Tenda releases updated firmware, implement defense-in-depth controls: disable remote management interfaces and restrict administrative access to trusted internal network segments only, change all default credentials to strong unique passwords immediately, implement network segmentation to isolate IoT devices from critical assets, monitor for suspicious POST requests to /goform/QuickIndex endpoints via intrusion detection systems, and consider replacing affected devices with alternative router models if Tenda does not provide timely security updates. Organizations should monitor the vendor security portal at https://www.tenda.com.cn/ and VulDB entry https://vuldb.com/?id.353654 for future patch availability announcements.

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2025-45429 CRITICAL POC
9.8 Apr 23

In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWp

Share

EUVD-2026-16472 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy