Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessDeliver crafted document to victim
-
DeliveryVictim opens document and activates hyperlink
-
ExploitNon-allowlisted URI scheme bypasses allowlist
-
ExecutionLaunch OS protocol handler with attacker arguments
-
ImpactExecute attacker-controlled action in user context
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V3 - Web Frontend Security Redirect URL validation
MITRE ATT&CK
1 technique across 1 tactic: Initial Access The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires that an application built on Telerik UI for WPF (versions prior to 2026.4.1110) opens an attacker-crafted document, and that the victim activates a hyperlink whose URI uses a scheme not on the product's allowlist; the flaw is that such a non-allowlisted scheme causes the application to launch the corresponding OS protocol handler with attacker-controlled arguments. Limiting factors: this is a local attack vector (AV:L) - the malicious document must be delivered to and opened by the user - and it requires user interaction (UI:R) to open the document and follow the link; it affects applications on the vulnerable version range, and updating to 2026.4.1110 or later is the vendor-stated remediation. |
| Impact | This is a credible but interaction-gated risk rather than a drop-everything emergency. The CVSS 3.1 vector (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H, base 7.8) describes high impact across confidentiality, integrity and availability, consistent with launching an OS protocol handler with attacker-controlled arguments (potential command/code execution). Crucially the vector is AV:L with UI:R: exploitation is not remote-unauthenticated-against-a-service but requires the victim to receive and open a crafted document and activate a hyperlink locally - so 'network-reachable mass exploitation' does not apply despite PR:N. The vuln.today decision label is 'this_week', indicating prioritized-but-not-immediate handling. No EPSS score, no CISA KEV listing, and no proof-of-concept reference are present in the input, so there is no signal of active or probable near-term exploitation; the only reference is the Progress/Telerik vendor advisory. Net: a genuine high-severity client-side vulnerability worth patching on a near-term (this-week) cadence, not a widely-wormable internet-facing flaw. |
| Exploit ScenarioDerived | An attacker crafts a document (or a hyperlink embedded in one) that uses a non-allowlisted URI scheme and sends it to a victim; when the victim opens the document in an application built on Telerik UI for WPF and activates the link, the application invokes the corresponding OS protocol handler with attacker-supplied arguments. This can be abused to run a handler/command of the attacker's choosing in the user's context. No public exploit identified at time of analysis, and successful exploitation depends on user interaction (opening the document and following the link). |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Nov 12, 2026
Untrusted URL redirection in Progress Telerik UI for WPF (versions prior to 2026.4.1110) causes applications built on the control suite to launch an arbitrary operating system protocol handler with attacker-controlled arguments when a user opens a crafted document and activates a hyperlink whose URI scheme is not on the product's allowlist. The flaw is unauthenticated per the CVSS vector (PR:N), but it is a local-vector, interaction-gated issue (AV:L/UI:R): the malicious document must be delivered to and opened by the victim, who must then follow the link, which is why it is rated 7.8 with high confidentiality, integrity and availability impact once triggered rather than treated as a remotely exploitable emergency. No public exploit has been identified at time of analysis, and the vendor-reviewed priority places it in the this_week remediation queue.
RemediationAI
Update to Telerik UI for WPF 2026.4.1110 or later, which is the vendor-stated remediation for this CVE; the vendor knowledge-base article at https://www.telerik.com/products/wpf/documentation/knowledge-base/kb-security-untrusted-url-redirection-cve-2026-124702 is the authoritative reference and should be read in full before rollout. Because the vulnerability lives in the redistributed UI assemblies, replacing the package on a build machine is not sufficient on its own: each affected application must be recompiled against the 2026.4.1110 (or later) assemblies and the rebuilt installer pushed to end users, since deployments still carrying the older Telerik binaries remain exposed, and post-deployment verification should confirm that the shipped application resolves the patched assembly version. No alternative workaround is documented in the available sources; until an application is rebuilt and redeployed, the only residual limiting factor is that exploitation requires the victim to open the crafted document and then activate the non-allowlisted hyperlink, so reducing the volume of untrusted documents and links reaching users of these applications lowers, but does not remove, exposure.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
Telerik UI for WPF is Progress Software's commercial control library for applications built on Windows Presentation Foundation, the .NET desktop UI framework, so the vulnerable code ships inside third-party desktop applications rather than in a standalone service. The issue is classified CWE-601 (URL Redirection to Untrusted Site, or 'Open Redirect'), but the practical mechanism described by the vendor goes beyond a browser-style redirect: the control handling a hyperlink hands the URI to the Windows shell so that the registered protocol handler for that scheme is started with the arguments embedded in the URI. The product maintains an allowlist of acceptable URI schemes, and the defect is that non-allowlisted schemes are not prevented from reaching that handler-launch path in versions prior to 2026.4.1110. The assessed severity (C:H/I:H/A:H) reflects that the handler is invoked with attacker-controlled arguments rather than a fixed, benign target; the specific handler behaviors and arguments an attacker could chain are not enumerated in the available source material. Only the WPF product line is identified in the CPE (cpe:2.3:a:progress_software:telerik_ui_for_wpf), and the trigger conditions beyond 'a crafted document plus a followed hyperlink' are not described in the available sources.
Know when Telerik Ui For Wpf gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Victim must open a crafted document locally (AV:L, UI:R) with no prior privileges (PR:N); launching a protocol handler with attacker arguments can yield full user-context compromise, so C/I/A:H.
Primary rating from Vendor (ProgressSoftware).
CVSS VectorVendor: ProgressSoftware
Lifecycle Timeline
2DescriptionCVE.org
In Telerik UI for WPF, versions prior to 2026.4.1110, an untrusted URL redirection vulnerability exists that allows an attacker to launch arbitrary operating system protocol handlers with attacker-controlled arguments via crafted documents and hyperlinks with a non-allowlisted URI scheme that the user opens.
Executive ViewAI
Progress Telerik UI for WPF (versions prior to 2026.4.1110) contains an untrusted URL redirection flaw that could allow an attacker to launch arbitrary operating system protocol handlers on a victim's machine after they open a crafted document. This impacts any organization using the affected control suite in their applications, potentially leading to unauthorized actions, data exposure, or system compromise. Leadership should care because it requires user interaction but can bypass security controls, and no patch is currently available, demanding immediate mitigation.
No vendor-released patch identified at time of analysis; interim mitigations include user awareness training to avoid opening untrusted documents and clicking embedded links, restricting protocol handler registrations via Group Policy or registry modifications, and enabling application allowlisting to block unauthorized protocol handlers.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
More in Telerik Ui For Wpf
View allDeserialization of untrusted data in Progress Telerik UI for WPF versions prior to 2026.4.1110 allows an attacker to per
Unauthorized code execution in applications built with Telerik UI for WPF versions before 2026.4.1110 is possible when a
EUVD-2026-124564
GHSA-2prq-35jw-rrcf
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB