Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain low-privilege CROSSBOW account
-
ExploitCraft request to schedule special operation
-
ExecutionBypass missing server-side authorization check
-
ImpactExecute unauthorized operation on managed devices
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V4 - API and Web Service Server-side security enforcement
|
| Exploitation Conditions | Exploitation requires an authenticated account on RUGGEDCOM CROSSBOW with at least minimal privileges (PR:L) and network reachability to the CROSSBOW server (AV:N); no user interaction is needed. The specific abused function is the request path that schedules 'special operations' on managed devices, where the server omits server-side authorization re-validation (CWE-602) and trusts client-enforced permissions. Limiting factors: the attacker must already possess valid (even if low-privilege) credentials and network access to the management interface, so unauthenticated internet exploitation is not possible; impact is bounded by what scheduled 'special operations' can affect on managed devices. All versions below V6.0 are affected; upgrading to V6.0 or later removes the condition. |
| Impact | This is a moderate-severity authorization flaw (CVSS 6.3, vendor-assigned by Siemens) in RUGGEDCOM CROSSBOW, mapped to CWE-602 (Client-Side Enforcement of Server-Side Security). The CVSS vector CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L indicates network-reachable, low-complexity exploitation requiring low existing privileges (PR:L, i.e. an authenticated low-privileged account) with no user interaction, yielding limited confidentiality, integrity, and availability impact. There is no EPSS score, no CISA KEV listing, and no public proof-of-concept in the provided data, so exploitation is characterized as 'no public exploit identified at time of analysis.' The signals are internally consistent: a low-privilege authenticated attacker can escalate their effective capability by scheduling operations they are not authorized to perform, because the server fails to re-validate authorization. This is a genuine privilege/authorization-boundary issue rather than an inflated high-CVSS score, but its real-world urgency is tempered by the authentication prerequisite and the limited (partial) impact ratings. The primary mitigating factor is the lack of evidence of active exploitation combined with the niche, access-controlled OT deployment context; the primary aggravating factor is that CROSSBOW manages access to critical substation/industrial infrastructure, so unauthorized scheduled operations could have outsized operational consequences despite the modest CVSS impact metrics. Prioritize patching, but this is not an emergency-tier flaw in the absence of KEV/POC signals. |
| Exploit ScenarioDerived | A low-privileged but authenticated CROSSBOW user (or an attacker who has obtained such credentials) sends a crafted request to schedule a special operation that their role should not permit. Because the server relies on client-side enforcement and does not re-check authorization server-side, the operation is accepted and queued against managed devices. No public exploit code is known, but the low attack complexity (AC:L) means a knowledgeable insider or credential-holder could reproduce this reliably. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 13, 2026
RUGGEDCOM CROSSBOW versions prior to V6.0 insufficiently enforce server-side authorization for requests that schedule special operations, allowing an authenticated attacker with minimal privileges to schedule unauthorized actions on managed devices. The flaw is a client-side enforcement of server-side security (CWE-602) that can be triggered remotely without user interaction, though the attacker must already have valid credentials and network access to the CROSSBOW server. Siemens has released V6.0 to correct the issue; no public exploit code has been identified at time of analysis.
RemediationAI
Vendor-released patch: RUGGEDCOM CROSSBOW V6.0 or later removes the missing server-side authorization check. Until patching is possible, reduce exposure by restricting network access to the CROSSBOW management interface to trusted administrative networks (e.g., via firewall rules or network segmentation) and by ensuring that only trusted accounts with necessary privileges are granted access; these measures limit the pool of potential low-privileged attackers but do not fix the underlying flaw. Monitor logs for unexpected scheduling of special operations on managed devices to detect abuse. Consult the Siemens advisory at https://cert-portal.siemens.com/productcert/html/ssa-508506.html for the authoritative patch details.
Affected VersionsENISA
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The vulnerability resides in the authorization logic of RUGGEDCOM CROSSBOW, a Siemens network management system for RUGGEDCOM industrial communications equipment. CWE-602 describes the root cause: the server relies on client-side enforcement of authorization decisions for scheduling 'special operations' rather than re-validating the user's privileges server-side on each request. As a result, a low-privileged authenticated user can craft or replay requests that the server trusts, bypassing the intended access controls. The affected CPE string cpe:2.3:a:siemens:ruggedcom_crossbow:*:*:*:*:*:*:*:* indicates all versions are potentially affected, with V6.0 being the first fixed release. The CVSS vector (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L) confirms the attack is network-reachable, needs low privileges, requires no user interaction, and has limited confidentiality, integrity, and availability impact.
Know when Ruggedcom Crossbow gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
Network-reachable management interface (AV:N) with low complexity (AC:L) abused by an authenticated low-privilege user (PR:L); missing server-side authz yields limited C/I/A impact without scope change.
Primary rating from Vendor (siemens).
CVSS VectorVendor: siemens
Lifecycle Timeline
1DescriptionCVE.org
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform server-side authorization checks for requests to schedule special operations. This could allow an authenticated attacker with minimal privileges to schedule unauthorized operations on devices.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
More in Ruggedcom Crossbow
View allA vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated critical severity (CVSS 9.8), thi
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). Rated critical severity (CVSS 9.8), thi
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). Rated high severity (CVSS 8.8), this vu
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). Rated high severity (CVSS 8.8), this vu
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). Rated high severity (CVSS 8.8), this vu
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated high severity (CVSS 8.8), this vu
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated high severity (CVSS 8.8), this vu
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). Rated high severity (CVSS 8.8), this vu
SQL injection in the firmware-upload filename handling of Siemens RUGGEDCOM CROSSBOW (all versions prior to V6.0) lets a
SQL injection in the Value field of notification conditions handled by the Notification Profile configuration in RUGGEDC
Authenticated SQL injection in Siemens RUGGEDCOM CROSSBOW (all versions prior to V6.0) allows a user with the specific p
Authenticated, low-privilege users of Siemens RUGGEDCOM CROSSBOW running any version earlier than V6.0 can bypass access
EUVD-2026-98403
GHSA-8g74-rfwv-m253
NVD
CVE.org
EPSS
Vulnrichment
VulDB
Exploit-DB