RUGGEDCOM CROSSBOW CVE-2026-89202

| EUVDEUVD-2026-98400 HIGH
Authorization Bypass Through User-Controlled Key (CWE-639)
2026-10-13 siemens GHSA-93m5-29fc-fvm2
7.1
CVSS 4.0 · Vendor: siemens
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain low-privilege Crossbow account
  2. Delivery
    Reach device management endpoint over network
  3. Exploit
    Send disconnect request for another user's session
  4. Execution
    Server skips authorization check
  5. Impact
    Victim sessions forcibly terminated (DoS)

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Object-level authorization, IDOR prevention
Exploitation Conditions

Exploitation requires a valid RUGGEDCOM CROSSBOW account with at least minimal privileges (PR:L) and network reachability to the application's device-disconnection function; no user interaction is needed. The core enabling condition is that the application does not authorization-check device-disconnection requests, so any authenticated user can target sessions belonging to other users or administrators. Limiting factors: the attacker must first obtain credentials (no unauthenticated path), impact is confined to availability/denial of service (sessions are dropped, not data compromised), and only deployments running versions below V6.0 are affected.

Impact

The provided CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H) is internally consistent with the description: a network-reachable, low-complexity attack requiring low privileges (PR:L) and no user interaction, impacting availability only (VA:H) with no confidentiality or integrity effect. This is a broken-authorization / IDOR-class issue (CWE-639), NOT a true authentication bypass - the attacker must already hold a valid, minimally-privileged account. No EPSS score, KEV listing, or POC indicator is present in the input, so exploitation likelihood cannot be quantified from these sources; there is no public exploit identified at time of analysis. Realistically this is a moderate-priority operational-availability issue rather than a critical remote-code-execution threat: the impact ceiling is denial of service (forcibly disconnecting other users' sessions, including administrators), and the PR:L prerequisite limits it to insiders or attackers who have already obtained credentials. For an industrial/OT access-management product the availability impact is non-trivial, so it warrants prompt patching, but the absence of confidentiality/integrity impact and the authentication prerequisite place it below internet-facing unauthenticated flaws in triage order.

Exploit ScenarioDerived

An attacker holding a low-privilege RUGGEDCOM CROSSBOW account (for example a rogue operator or a user whose credentials were phished) issues a device-disconnection request that the application fails to authorization-check against the target session. By repeatedly disconnecting other users' and administrators' active sessions, the attacker denies legitimate operators access to managed substation devices. No public exploit code is identified at time of analysis, and because privileges are required (PR:L), the attacker must first obtain a valid account.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.4% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv2 – Oct 13, 2026

Authenticated attackers with minimal privileges can disconnect active sessions of other users, including administrators, in Siemens RUGGEDCOM CROSSBOW versions prior to V6.0 due to missing authorization checks on device-disconnection requests, causing a denial of service. The flaw is network-reachable, requires low privileges (PR:L) and no user interaction, and affects only availability (VA:H) with no confidentiality or integrity impact. No public exploit code or active exploitation (CISA KEV) has been identified at time of analysis.

Earlier versions of this analysis (1)
v1 Oct 13, 2026 - 10:10 CVSS 6.5

Authenticated low-privilege users can disconnect active sessions of other users, including administrators, in RUGGEDCOM CROSSBOW versions before V6.0 due to missing authorization checks on device disconnection requests. This denial-of-service flaw (CVSS 6.5) requires a valid account (PR:L) and network access, and impacts only availability. No public exploit has been identified at time of analysis, though a vendor advisory is available.

RemediationAI

Update to RUGGEDCOM CROSSBOW V6.0 or later. Vendor-released patch: V6.0, as indicated by the version boundary in the CVE description and the Siemens advisory SSA-508506 (https://cert-portal.siemens.com/productcert/html/ssa-508506.html), which provides download links and installation instructions. If immediate upgrade is not possible, restrict network access to the device-disconnection function to trusted administrative subnets, monitor logs for unexpected session terminations, and consider disabling the feature if it is not essential. Note that because the vulnerability requires only low privileges, restricting access to authenticated users may not fully mitigate if any account is compromised; network segmentation and strict access controls are therefore recommended as compensating controls, with the trade-off of reduced flexibility for legitimate remote management.

Affected VersionsENISA

RUGGEDCOM CROSSBOW 0 <V6.0

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

RUGGEDCOM CROSSBOW is a Siemens secure remote access and device management platform used in industrial environments. The vulnerability resides in the device-disconnection function, which does not validate that the requesting user has authority over the target session. This is an instance of CWE-639: Authorization Bypass Through User-Controlled Key, where a session identifier (or similar key) is supplied by the client, but the server fails to verify ownership before acting on it. Consequently, a low-privileged authenticated user can terminate other users' sessions by sending crafted disconnection requests. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H) confirms network exploitability, low attack complexity, low privileges required, no user interaction, and high availability impact only. The CPE string cpe:2.3:a:siemens:ruggedcom_crossbow:*:*:*:*:*:*:*:* identifies the affected product family.

Know when Ruggedcom Crossbow gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (siemens) PRIMARY 7.1 MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
vuln.today AI 6.5 MEDIUM

Network-reachable low-complexity action by an authenticated minimal-privilege user (PR:L), no UI; impact is denial of service only, so A:H with C:N/I:N and unchanged scope.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (siemens).

CVSS VectorVendor: siemens

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
None
Vulnerable system: Integrity
None
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
Severity Changed
Oct 13, 2026 - 10:22 NVD
MEDIUM HIGH
CVSS changed
Oct 13, 2026 - 10:22 NVD
6.5 (MEDIUM) 7.1 (HIGH)

DescriptionCVE.org

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service.

Executive ViewAI

Why It Matters

Siemens RUGGEDCOM CROSSBOW, a platform for managing rugged communications networks, has a high-severity weakness that lets users with basic authenticated access interrupt other operators' sessions, including administrators. This can cause unplanned outages or loss of visibility in environments that rely on continuous network control, affecting operations and incident response. No vendor-released patch identified at time of analysis, so leadership should treat this as a near-term operational resilience issue and prioritize interim access, segmentation, and monitoring controls.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis; interim mitigations include restricting management-plane access to trusted networks, enforcing least privilege and disabling dormant accounts, segmenting affected CROSSBOW systems, monitoring for session-disconnection events, and coordinating with Siemens for patch or fixed-version guidance.

Threat Intelligence Overview

EPSS Score
0.4%
Top 71% exploitable
Prevalence
Low
niche Siemens OT/substation access-management software, industry-specific footprint
Social Media
1
Sightings
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.4%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

36
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +36
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.

CVE-2024-27939 CRITICAL
9.8 May 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated critical severity (CVSS 9.8), thi

CVE-2023-37372 CRITICAL
9.8 Aug 08

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). Rated critical severity (CVSS 9.8), thi

CVE-2024-27941 HIGH
8.8 May 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated high severity (CVSS 8.8), this vu

CVE-2024-27940 HIGH
8.8 May 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated high severity (CVSS 8.8), this vu

CVE-2023-27411 HIGH
8.8 Aug 08

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). Rated high severity (CVSS 8.8), this vu

CVE-2023-27463 HIGH
8.8 Mar 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). Rated high severity (CVSS 8.8), this vu

CVE-2023-27310 HIGH
8.8 Mar 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). Rated high severity (CVSS 8.8), this vu

CVE-2023-27309 HIGH
8.8 Mar 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). Rated high severity (CVSS 8.8), this vu

CVE-2026-89198 HIGH
8.7 Oct 13

SQL injection in the firmware-upload filename handling of Siemens RUGGEDCOM CROSSBOW (all versions prior to V6.0) lets a

CVE-2026-89197 HIGH
8.7 Oct 13

SQL injection in the Value field of notification conditions handled by the Notification Profile configuration in RUGGEDC

CVE-2026-89196 HIGH
8.7 Oct 13

Authenticated SQL injection in Siemens RUGGEDCOM CROSSBOW (all versions prior to V6.0) allows a user with the specific p

CVE-2026-89199 HIGH
8.7 Oct 13

Authenticated, low-privilege users of Siemens RUGGEDCOM CROSSBOW running any version earlier than V6.0 can bypass access

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy