Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CSRF requires no attacker privileges (PR:N) but mandates victim interaction (UI:R); full device state control yields C:H/I:H/A:H within unchanged scope.
Primary rating from Vendor (hq).
CVSS VectorVendor: hq
Lifecycle Timeline
2DescriptionCVE.org
Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior are vulnerable to a cross-site request forgery vulnerability. This could allow an attacker to perform state changing operations on the device.
AnalysisAI
Cross-site request forgery in Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior allows a remote unauthenticated attacker to perform unauthorized state-changing operations on an industrial DC power monitoring device by tricking an authenticated administrator into visiting a malicious webpage. Reported via CISA ICS-CERT advisory ICSA-26-246-08, the vulnerability is rooted in a missing anti-CSRF mechanism in the device web interface; a firmware upgrade to v2.4.2 is available. …
Unlock full vulnerability intelligence
- Risk assessment & exploitation conditions
- Attack chain visualization
- Remediation with exact patch versions
- Threat intelligence from 22 sources
- Personal watchlist & email alerts
Free forever · No credit card required
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata
Vulnerability AssessmentAI
| Exploitation | Exploitation requires that a device administrator maintain an active authenticated session with the TPDIN-Monitor-WEB3 web interface while simultaneously visiting an attacker-controlled webpage. … Additional conditions and limiting factors are described in the full assessment. |
| Risk Assessment | The CVSS 4.0 score of 8.6 reflects the high impact potential (VC:H/VI:H/VA:H) of unauthorized configuration or control operations on a power monitoring device, but the UI:A requirement is the decisive constraint - the attack cannot proceed without a currently authenticated administrator actively visiting an attacker-controlled resource. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in. |
| Exploit Scenario | Full exploit scenario with step-by-step reproduction available after sign-in. |
| Remediation | Upgrade TPDIN-Monitor-WEB3 firmware to version 2.4.2 using the images published by Tycon Systems and referenced in CISA ICS advisory ICSA-26-246-08 (https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-08). … Detailed patch versions, workarounds, and compensating controls in full report. |
Recommended ActionAI
Within 24 hours, conduct a complete inventory of all TPDIN-Monitor-WEB3 devices currently deployed and identify which are running firmware version 2.2.9 or earlier, prioritizing systems that support production power distribution. …
Sign in for detailed remediation steps and compensating controls.
Threat intelligence, references, and detailed analysis are available after sign-in.
Same weakness CWE-352 – Cross-Site Request Forgery (CSRF)
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2026-71753
GHSA-wg4h-wx9p-hqrr