Skip to main content

TPDIN-Monitor-WEB3 CVE-2026-82712

| EUVDEUVD-2026-71753 HIGH
Cross-Site Request Forgery (CSRF) (CWE-352)
2026-09-04 ics-cert@hq.dhs.gov GHSA-wg4h-wx9p-hqrr
8.6
CVSS 4.0 · Vendor: hq
Share

Severity by source

Vendor (hq) PRIMARY
8.6 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
8.8 HIGH

CSRF requires no attacker privileges (PR:N) but mandates victim interaction (UI:R); full device state control yields C:H/I:H/A:H within unchanged scope.

3.1 AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (hq).

CVSS VectorVendor: hq

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
A
Scope
X

Lifecycle Timeline

2
Analysis Generated
Sep 04, 2026 - 21:31 vuln.today
CVE Published
Sep 04, 2026 - 21:17 cve.org
HIGH 8.6

DescriptionCVE.org

Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior are vulnerable to a cross-site request forgery vulnerability. This could allow an attacker to perform state changing operations on the device.

AnalysisAI

Cross-site request forgery in Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior allows a remote unauthenticated attacker to perform unauthorized state-changing operations on an industrial DC power monitoring device by tricking an authenticated administrator into visiting a malicious webpage. Reported via CISA ICS-CERT advisory ICSA-26-246-08, the vulnerability is rooted in a missing anti-CSRF mechanism in the device web interface; a firmware upgrade to v2.4.2 is available. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires that a device administrator maintain an active authenticated session with the TPDIN-Monitor-WEB3 web interface while simultaneously visiting an attacker-controlled webpage. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 4.0 score of 8.6 reflects the high impact potential (VC:H/VI:H/VA:H) of unauthorized configuration or control operations on a power monitoring device, but the UI:A requirement is the decisive constraint - the attack cannot proceed without a currently authenticated administrator actively visiting an attacker-controlled resource. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Upgrade TPDIN-Monitor-WEB3 firmware to version 2.4.2 using the images published by Tycon Systems and referenced in CISA ICS advisory ICSA-26-246-08 (https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-08). … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours, conduct a complete inventory of all TPDIN-Monitor-WEB3 devices currently deployed and identify which are running firmware version 2.2.9 or earlier, prioritizing systems that support production power distribution. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

CVE-2026-82712 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy