Skip to main content

Dell PowerStore CVE-2026-79685

| EUVDEUVD-2026-69218 MEDIUM
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') (CWE-88)
2026-09-01 dell GHSA-4jmv-9vjw-mj58
6.5
CVSS 3.1 · Vendor: dell
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain low-privileged PowerStore credentials
  2. Delivery
    Access management API or CLI over network
  3. Exploit
    Craft malicious argument injection payload
  4. Execution
    Submit request to vulnerable endpoint
  5. Persist
    Bypass argument parsing restrictions
  6. Impact
    Retrieve sensitive system information

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Argument sanitization
Exploitation Conditions

Exploitation requires a valid PowerStore management account with at least limited (low) privileges - unauthenticated exploitation is not possible per the CVSS PR:L metric. The attack is reachable over the network (AV:N) with no special configuration or non-default deployment required (AC:L), and no victim user interaction is needed (UI:N). Exploitation is limited by the authentication prerequisite: an attacker must possess or obtain valid credentials for any PowerStore management account, even a low-privileged one such as a monitoring or read-only role. Impact is confined to confidentiality - the flaw does not enable data modification or service disruption (I:N, A:N). No specific non-default feature or protocol configuration is documented as a prerequisite beyond authenticated network access to the management interface.

Impact

The CVSS base score of 6.5 (Medium) reflects the combination of network accessibility, low attack complexity, and high confidentiality impact offset by the authentication requirement (PR:L). No EPSS data was provided, and the vulnerability is not listed in CISA KEV, indicating no confirmed active exploitation at time of analysis. The tag 'Authentication Bypass' in the input is a mislabeling - the description clearly states exploitation requires an authenticated session with limited privileges, not a bypass of authentication itself. The high C impact suggests sensitive material such as credentials, configuration data, or system internals may be exposed. Real-world risk is elevated in environments where the PowerStore management interface is accessible to multiple internal users with varying trust levels, as any low-privileged account could leverage this flaw. The absence of integrity or availability impact limits the blast radius to data exposure rather than operational disruption.

Exploit ScenarioDerived

An insider threat or attacker who has compromised a low-privileged PowerStore management account sends a crafted request to a PowerStore management API or CLI endpoint, injecting additional arguments into an underlying system call. The injected arguments redirect output or enable access to system-level information - such as configuration files, credentials, or storage topology details - that the limited account role should not be permitted to read. No public exploit code exists at time of analysis, but the low attack complexity means exploitation would require only basic knowledge of the injection point.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
Patch available 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Sep 01, 2026

Argument Injection in Dell PowerStore storage appliances allows an authenticated low-privileged user to extract sensitive system information over the network without requiring additional interaction. The vulnerability (CWE-88) arises from improper neutralization of user-controlled input passed as arguments to an internal process, enabling privilege escalation of read access beyond what the account's role should permit. No public exploit code or active exploitation has been identified at time of analysis, though the low attack complexity and network accessibility make this a credible insider and compromised-credential threat.

RemediationAI

Apply the security update detailed in Dell Security Advisory DSA-2026-330, available at https://www.dell.com/support/kbdoc/en-us/000497829/dsa-2026-330-dell-powerstore-t-security-update-for-multiple-vulnerabilities. No specific patched firmware version number was provided in the available data - consult the advisory directly to obtain the exact target version for each appliance model. As a compensating control prior to patching, restrict management plane access to trusted administrative networks using firewall rules or dedicated management VLANs, limiting exposure to only users who legitimately require management access. Additionally, audit current PowerStore user accounts and revoke or restrict low-privileged accounts that do not require management interface access. Note that restricting network access does not eliminate the vulnerability for internally-positioned threat actors but significantly reduces the attack surface.

Affected VersionsENISA

PowerStore 9000T 0 <4.3.1.2-2771239 or later
PowerStore 3000T 0 <4.3.1.2-2771239 or later
PowerStore 3200Q 0 <4.3.1.2-2771239 or later
PowerStore 5200T 0 <4.1.0.6-2771237 or later
PowerStore 5000T 0 <4.3.1.2-2771239 or later
PowerStore 5200Q 0 <4.3.1.2-2771239 or later
PowerStore 3200T 0 <4.1.0.6-2771237 or later
PowerStore 7000T 0 <4.1.0.6-2771237 or later
PowerStore 5000T 0 <4.1.0.6-2771237 or later
PowerStore 7000T 0 <4.3.1.2-2771239 or later
PowerStore 1000T 0 <4.1.0.6-2771237 or later
PowerStore 500T 0 <4.1.0.6-2771237 or later
PowerStore 1200T 0 <4.1.0.6-2771237 or later
PowerStore 9000T 0 <4.1.0.6-2771237 or later
PowerStore 1000T 0 <4.3.1.2-2771239 or later
PowerStore 5200Q 0 <4.1.0.6-2771237 or later
PowerStore 9200T 0 <4.3.1.2-2771239 or later
PowerStore 3000T 0 <4.1.0.6-2771237 or later
PowerStore 500T 0 <4.3.1.2-2771239 or later
PowerStore 3200Q 0 <4.1.0.6-2771237 or later
PowerStore 5200T 0 <4.3.1.2-2771239 or later
PowerStore 9200T 0 <4.1.0.6-2771237 or later
PowerStore 3200T 0 <4.3.1.2-2771239 or later
PowerStore 1200T 0 <4.3.1.2-2771239 or later

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

CWE-88 (Argument Injection or Modification) occurs when user-supplied data is incorporated into command arguments without proper sanitization, allowing an attacker to inject additional arguments that alter the behavior of the underlying process. Dell PowerStore is an enterprise all-flash and hybrid storage platform; the affected CPEs span models 500T through 7000T (with tags also referencing 9000T and 9200T, not present in CPE data). The CVSS vector AV:N/AC:L/PR:L indicates the vulnerability is reachable over the network, requires no special conditions, and only a low-privileged authenticated account - consistent with a storage management API or CLI endpoint that inadequately validates input before passing it to an internal system call or utility.

Know when Powerstore 500T gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (dell) PRIMARY 6.5 MEDIUM
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
vuln.today AI 6.5 MEDIUM

Network-accessible management interface, low-privileged account required, no integrity or availability impact - aligns with vendor-provided vector.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (dell).

CVSS VectorVendor: dell

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

1
Patch available
Sep 01, 2026 - 16:02 EUVD

DescriptionCVE.org

Dell PowerStore contains an Argument Injection vulnerability. An authenticated user with limited privileges could potentially exploit this vulnerability to gain unauthorized access to sensitive sensitive system information.

Threat Intelligence Overview

EPSS Score
0.2%
Top 88% exploitable
Prevalence
Medium
enterprise all-flash storage, common in mid-to-large data centers
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.2%
Patch available Yes
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact· derived
Medium
Technical Impact
Partial

Priority Score

32
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +32
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0
CVE-2026-116449 CRITICAL
9.8 Nov 18

Dell PowerStore SDNAS on affected PowerStore NAS nodes is vulnerable to unauthenticated OS command injection that can le

CVE-2026-116448 CRITICAL
9.8 Nov 18

OS command injection in Dell PowerStore T-series SDNAS allows attackers with internal network reachability to execute ar

CVE-2026-116440 CRITICAL
9.8 Nov 19

Unauthenticated remote code execution or denial of service against Dell PowerStore T-series NAS nodes is possible via a

CVE-2026-116443 CRITICAL
9.8 Nov 18

Dell PowerStore storage appliances running the SDNAS NAS service contain an unauthenticated remote stack-based buffer ov

CVE-2026-67271 CRITICAL
9.8 Aug 18

Remote code execution and denial of service in Dell PowerStore T-series arrays (SDNAS software) stem from an out-of-boun

CVE-2026-58574 CRITICAL
9.8 Aug 31

Unauthenticated information disclosure in Dell PowerStore T-series storage appliances allows an attacker with network ac

CVE-2026-116441 CRITICAL
9.6 Nov 18

Out-of-bounds write in the Dell PowerStore storage-processor interconnect driver lets a malicious peer on the array's in

CVE-2026-111508 CRITICAL
9.1 Nov 18

OS command injection in Dell PowerStore T- and Q-series storage appliances allows an attacker who already holds high-pri

CVE-2026-103813 CRITICAL
9.1 Nov 13

OS command injection in Dell PowerStore storage appliances allows an authenticated management-plane user to execute oper

CVE-2026-58571 HIGH
8.8 Sep 01

OS command injection in Dell PowerStore storage appliances enables a locally authenticated user with limited privileges

CVE-2026-79682 HIGH
8.8 Sep 01

Command injection in Dell PowerStore storage appliances allows an authenticated low-privileged local user to execute arb

CVE-2026-82156 HIGH
8.8 Nov 16

An authorization bypass in Dell PowerStore storage appliances lets a user who already holds valid low-privileged credent

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy