Skip to main content

Tenda CVE-2026-4551

| EUVDEUVD-2026-14312 HIGH
Stack-based Buffer Overflow (CWE-121)
2026-03-22 VulDB GHSA-2mxw-7frq-fx3r
7.4
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

4
PoC Detected
Apr 02, 2026 - 20:50 vuln.today
Public exploit code
EUVD ID Assigned
Mar 22, 2026 - 14:45 euvd
EUVD-2026-14312
Analysis Generated
Mar 22, 2026 - 14:45 vuln.today
CVE Published
Mar 22, 2026 - 14:31 nvd
HIGH 7.4

DescriptionCVE.org

A vulnerability was found in Tenda F453 1.0.0.3. This vulnerability affects the function fromSafeClientFilter of the file /goform/SafeClientFilter of the component Parameters Handler. Performing a manipulation of the argument menufacturer/Go results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been made public and could be used.

AnalysisAI

Tenda F453 version 1.0.0.3 contains a stack-based buffer overflow in the SafeClientFilter parameter handler that allows authenticated remote attackers to execute arbitrary code by manipulating the manufacturer/Go argument. Public exploit code exists for this vulnerability and no patch is currently available, creating significant risk for affected deployments.

Technical ContextAI

The vulnerability affects the Tenda F453 router (CPE: cpe:2.3:a:tenda:f453:*:*:*:*:*:*:*:*) running firmware version 1.0.0.3. This is classified as CWE-121 (Stack-based Buffer Overflow), a memory corruption vulnerability that occurs when a program writes more data to a buffer located on the stack than it was allocated to hold. The affected function fromSafeClientFilter in the /goform/SafeClientFilter endpoint of the Parameters Handler component fails to properly validate input length for the 'menufacturer' and 'Go' parameters. When these parameters are manipulated with oversized input, they overflow the allocated stack buffer, potentially overwriting return addresses, function pointers, or other critical stack data. This class of vulnerability can lead to arbitrary code execution as the attacker can control the instruction pointer by carefully crafting the overflow payload to redirect program execution to malicious code.

RemediationAI

As of this analysis, no official patch or firmware update has been explicitly referenced in the available intelligence sources, indicated by the CVSS Remediation Level of 'X' (unavailable). Users of Tenda F453 firmware version 1.0.0.3 should immediately check the official Tenda website at https://www.tenda.com.cn/ for any available firmware updates that address this vulnerability and apply them as soon as possible. Until an official patch is available or can be deployed, implement the following mitigations: disable remote management interfaces and restrict administrative access to the router to trusted local network segments only, enforce strong non-default administrative credentials to raise the privilege requirement bar, consider deploying the affected devices behind additional network segmentation or firewall controls to limit exposure, and if the SafeClientFilter functionality is not required for operations, disable it if possible through the router's configuration interface. Organizations should also monitor VulDB entries https://vuldb.com/?id.352378 and the GitHub repository https://github.com/Litengzheng/vul_db/blob/main/F453/vul_86/README.md for updates on exploitation activity and potential workarounds.

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2025-45429 CRITICAL POC
9.8 Apr 23

In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWp

Share

CVE-2026-4551 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy