Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain low-privilege SystemLink account credentials
-
DeliverySend crafted network request referencing restricted host OS file path
-
ExploitTrigger missing authorization check (CWE-862)
-
ExecutionAccess host OS files outside application boundary
-
ImpactExfiltrate sensitive host data or write to protected directories
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Authorization checks on every request
MITRE ATT&CK
1 technique across 1 tactic: Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires a valid NI SystemLink user account with limited (low) privileges - unauthenticated access is not possible per the CVSS 4.0 PR:L metric. The SystemLink server must be network-reachable from the attacker, which is the typical deployment configuration. No non-default feature, protocol, or configuration setting is required; the flaw affects standard installations at or before version 26.5.0. Exploitation is bounded by the requirement to hold any SystemLink account credential: organizations that tightly control user account provisioning, enforce multi-factor authentication, or isolate SystemLink to air-gapped networks significantly reduce real-world risk. |
| Impact | The vendor-assigned CVSS 4.0 score of 8.6 (High) reflects a network-reachable, low-complexity flaw exploitable by any authenticated low-privilege account. The VC:H and VI:H metrics indicate both high confidentiality and integrity impact on the vulnerable system, though the description explicitly references only 'access' to files and directories - the integrity (VI:H) component implies write capability but is not explicitly confirmed in the description text and should be independently verified against the vendor advisory. No EPSS data is provided in the input, and the vulnerability is absent from CISA KEV, indicating no observed active exploitation at time of analysis. Despite the high CVSS score, the limited production footprint of NI SystemLink in industrial test environments constrains the overall attack surface. For organizations running SystemLink in multi-user network configurations - particularly shared lab or manufacturing environments - the risk is material: any low-privilege account could potentially exfiltrate host configuration, credentials, or sensitive operational data from the underlying OS. |
| Exploit ScenarioDerived | An attacker with a valid low-privilege NI SystemLink account - obtained via credential theft, default credentials, or account registration if allowed - submits crafted API or file-access requests referencing restricted host OS file paths, such as credential stores or configuration directories. The application's missing authorization check fails to block these requests, and the attacker reads (and potentially writes) files outside the intended application boundary. No public proof-of-concept exists at time of analysis, but the straightforward nature of a path-traversal-style authorization bypass makes independent discovery feasible. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv2 – Sep 10, 2026
Improper access control in NI SystemLink and NI SystemLink Server (all versions through 26.5.0, 2026 Q3) allows a network-authenticated user with limited privileges to access host operating system files and directories that should be restricted. The root cause is CWE-862 (Missing Authorization) - the application authenticates the user but fails to enforce authorization boundaries between SystemLink application scope and the underlying host OS file system. No active exploitation or public proof-of-concept has been identified at time of analysis; the vulnerability is confirmed by NI's own security advisory.
Earlier versions of this analysis (1)
Improper access control in NI SystemLink permits authenticated low-privilege users to traverse beyond their authorized scope and access host operating system files and directories that should be restricted. Both the SystemLink application server and SystemLink Server products are affected through the 2026 Q3 release. No public exploit code or active exploitation has been identified at time of analysis, but the combination of network accessibility, low authentication bar, and high confidentiality/integrity impact makes this a meaningful risk for organizations running NI's test-and-measurement management infrastructure.
RemediationAI
Consult the NI security advisory at https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/2026/improper-access-controls-in-ni-systemlink.html to obtain and apply the vendor-released patch; the EUVD lists all releases through 26.5.0 as affected, so the fix is expected in a release beyond 26.5.0, but the exact patched version number must be confirmed from the advisory before upgrading. As compensating controls while patching is coordinated, restrict SystemLink server network access to only trusted management hosts via host-based or network firewall rules to prevent opportunistic exploitation. Audit all SystemLink user accounts and revoke or downgrade any unnecessary accounts, as all low-privilege accounts are potential exploit paths. Enable and monitor host OS file-system audit logging (e.g., auditd on Linux, Windows Security Event Log) to detect anomalous file-path access patterns originating from the SystemLink process.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 2 packages in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
NI SystemLink is National Instruments' (now Emerson) enterprise platform for centralized management of test, measurement, and IoT systems, typically deployed in industrial and R&D environments. The affected components are identified by CPE strings cpe:2.3:a:ni:systemlink:*:*:*:*:*:*:*:* and cpe:2.3:a:ni:systemlink_server:*:*:*:*:*:*:*:*, covering all versions through 26.5.0. The flaw is classified as CWE-862 (Missing Authorization), meaning the server-side logic does not validate whether an authenticated low-privilege user has the right to access file paths on the host operating system - a classic application-to-host boundary confusion. The vendor-assigned CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N) confirms network exploitability by any low-privilege account with no user interaction and no special attack conditions required.
Know when Systemlink gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N
Network-reachable by low-privilege account (PR:L); no user interaction; C:H/I:H consistent with vendor CVSS 4.0 VC:H/VI:H; no availability impact indicated; scope unchanged as impact is on the host itself.
Primary rating from Vendor (NI).
CVSS VectorVendor: NI
Lifecycle Timeline
3DescriptionCVE.org
There is an improper access control vulnerability in NI SystemLink that may allow an authenticated user with limited privileges to access host operating system files and directories that should be restricted. This vulnerability affects NI SystemLink and NI SystemLink Server 2026 Q3 and prior versions.
Executive ViewAI
NI SystemLink and NI SystemLink Server through version 26.5.0 contain a critical authorization flaw allowing authenticated users with limited application privileges to directly access restricted operating system files and directories. Organizations running affected versions risk exposure of sensitive system configuration, credentials, and other confidential data housed on the host OS, with no vendor patch currently available to remediate the vulnerability.
Enforce restrictive OS-level file and directory permissions on hosts running NI SystemLink to deny the service account access to sensitive OS directories outside its operational scope; implement network segmentation to restrict NI SystemLink server communication to dedicated administrative network segments; deploy continuous monitoring and audit logging for file-access attempts by NI SystemLink processes to detect unauthorized data exposure; run NI SystemLink service accounts with minimal required privileges (principle of least privilege) to limit the scope of accessible data.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
More in Systemlink
View allCleartext storage of sensitive information in NI SystemLink and NI SystemLink Server (all versions through 2026 Q3, ≤26.
An out-of-date version of Redis shipped with NI SystemLink Server is susceptible to multiple vulnerabilities, including
There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Ra
An incorrect permission in the installation directory for the shared NI SystemLink Server KeyValueDatabase service may r
EUVD-2026-75564
GHSA-f777-xf39-r6fm
NVD
CVE.org
EPSS
Vulnrichment
VulDB
Exploit-DB