Danfoss AK-SM 800 CVE-2026-127057

| EUVDEUVD-2026-131451 CRITICAL
Use of Default Credentials (CWE-1392)
2026-11-20 d7ff35af-cf88-454c-bab9-af60602f10f8 GHSA-cmpj-p5g3-48x8
9.9
CVSS 4.0 · Vendor: d7ff35af-cf88-454c-bab9-af60602f10f8
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Reach controller management interface
  2. Exploit
    Authenticate with documented default credentials
  3. Execution
    Gain full administrative access
  4. Impact
    Manipulate refrigeration control and settings

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Default credential prevention
Exploitation Conditions

Exploitation requires network reachability to the authentication interface of a Danfoss AK-SC 355 or AK-SM 800 Series controller while it still uses the credentials documented in the product manual (or otherwise known passwords). There are no special feature or configuration prerequisites - any affected unit (all versions) authenticating with the documented defaults is vulnerable. The key limiting factor is deployment: if operators changed the documented default credentials and the device is not otherwise reachable, exploitation via the published defaults fails; conversely, these are OT controllers normally on segmented networks, so real-world exploitability hinges on whether the interface is exposed to the attacker.

Impact

All signals point the same direction: the provided CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N, score 9.9) describes a remote, low-complexity, no-privilege, no-interaction flaw, and the vuln.today Decision label is act_now, so this should be treated as a priority rather than a high-CVSS-but-low-real-risk item. The mechanism is CWE-1392 (use of default credentials), with the defaults documented in the public product manual, meaning the 'secret' is effectively public knowledge and the only real barrier is network reachability. Important caveats: no EPSS score, no CISA KEV entry, and no PoC reference were supplied, so there is no evidence of confirmed active exploitation or a measured exploitation probability - the urgency comes from the act_now label and the trivial exploitability, not from observed in-the-wild activity. Because these are OT/refrigeration controllers typically expected to sit on segmented networks, the practical risk is dominated by whether the AK-SC 355 / AK-SM 800 management interface is actually exposed to attackers.

Exploit ScenarioDerived

An attacker who can reach the management interface of a Danfoss AK-SC 355 or AK-SM 800 controller logs in using the credentials documented in the product manual, with no exploit code required. Because the CVSS vector is PR:N/UI:N, this needs no prior privileges or user interaction, only network access to the device, after which the attacker has full control. No public exploit identified at time of analysis, as the attack is simply authenticating with known defaults.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 0.7% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Nov 20, 2026

Unauthorized access to Danfoss legacy AK-SC 355 and AK-SM 800 series controllers is possible because those units were shipped with default credentials documented in the product manual, and all versions remain affected. The supplied CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N, base 9.9) describes a remote, low-complexity, unauthenticated attack with no user interaction and high confidentiality, integrity and availability impact, and the vuln.today decision label is act_now. Exploitation in practice requires network reachability to the controller's authentication interface on a unit that still authenticates with the documented defaults; no public exploit code and no CISA KEV entry were identified at time of analysis.

RemediationAI

The provided data does not include a fixed firmware or software version for this CVE, and patch status is not confirmed in the available sources; the Danfoss security advisory DSA-2026-12-02 (https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2026-12-02/) should be treated as the authoritative source for a fixed release and for the vendor's own guidance. The exposure described is entirely the persistence of credentials documented in the product manual, so the primary operational control is to change the documented default credentials on every AK-SC 355 and AK-SM 800 unit and to verify that they were in fact changed during commissioning - the trade-off is operational: credential changes must be tracked and applied consistently across all units or the fleet reverts to the shared documented values. As a compensating control, restrict network reachability to the controller's authentication interface using segmentation and firewall rules between the OT control network and IT/business networks, accepting that this narrows remote management paths and requires maintaining access rules for authorized engineering workstations.

Affected VersionsENISA

AK-SC 355 0 ≤latest
AK-SM 800 0 ≤latest

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The flaw is CWE-1392 (Use of Default Credentials) in Danfoss legacy refrigeration/supermarket controllers of the AK-SC 355 and AK-SM 800 families - OT devices used for rack and CO2 control. The authentication design relies on credentials that were manufactured into the products and published in the product manual, so anyone who can reach the authentication interface and has read the manual can present valid credentials rather than defeat a cryptographic control. The attacker's effort therefore reduces to two conditions stated in the independent assessment: reachability of the authentication interface, and a unit that has not had the documented default credentials changed. Nothing in the available sources describes a memory-safety or protocol parsing weakness, a race condition, or any bypass of passwords that were actually changed; the exposure is the persistence of published credentials on deployed units. Because these are OT controllers, real-world exploitability hinges on whether the interface is segmented from untrusted networks or reachable from them.

Know when Danfoss gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (d7ff35af-cf88-454c-bab9-af60602f10f8) PRIMARY 9.9 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H
vuln.today AI 10.0 CRITICAL

Documented default credentials over a network interface give AV:N/AC:L/PR:N/UI:N; full device takeover plus impact on the controlled refrigeration process justifies S:C with C/I/A:H.

3.1 AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H

Primary rating from Vendor (d7ff35af-cf88-454c-bab9-af60602f10f8).

CVSS VectorVendor: d7ff35af-cf88-454c-bab9-af60602f10f8

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
Low
Subsequent system: Integrity
Low
Subsequent system: Availability
High

DescriptionCVE.org

The Danfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized access when default credentials or known passwords are used for authentication. These products were manufactured with default credentials documented in the product manual. All versions are affected.

Executive ViewAI

Why It Matters

Danfoss AK-SC 355 and AK-SM 800 legacy controllers ship with documented default credentials that remain unchanged across all versions, enabling unauthenticated remote attackers with network access to fully compromise these devices. This critical flaw affects operational technology environments, potentially disrupting refrigeration and HVAC systems, and leadership must act urgently to prevent unauthorized access and physical process disruption.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations include immediately changing default credentials, restricting network access to controllers, and implementing network segmentation.

Threat Intelligence Overview

EPSS Score
0.7%
Top 46% exploitable
Prevalence
Low
legacy, industry-specific refrigeration/HVAC OT controllers, niche deployment
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.7%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
Yes
Human Impact
High
Technical Impact
Total

Priority Score

51
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +50
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

CVE-2023-22583 CRITICAL
9.8 Jun 11

The Danfoss AK-EM100 web forms allow for SQL injection in the login forms. Rated critical severity (CVSS 9.8), this vuln

CVE-2026-15203 CRITICAL
9.3 Aug 26

Improper access control on the debug and engineering interfaces of Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid

CVE-2026-129713 CRITICAL
9.3 Nov 20

Unauthenticated remote attackers can overflow a stack buffer in the CGI handler of the Danfoss AK-SM 8xxA series control

CVE-2023-25915 HIGH
8.8 Aug 21

Due to improper input validation, an authenticated remote attacker could execute arbitrary commands on the target system

CVE-2023-25914 HIGH
8.8 Aug 21

Due to improper restriction, authenticated attackers could retrieve and read system files of the underlying server throu

CVE-2023-25911 HIGH
8.8 Jun 11

The Danfoss AK-EM100 web applications allow for an authenticated user to perform OS command injection through the web ap

CVE-2023-25913 HIGH
7.5 Aug 21

Because of an authentication flaw an attacker would be capable of generating a web report that discloses sensitive infor

CVE-2023-22586 HIGH
7.5 Jun 11

The Danfoss AK-EM100 web applications allow for Local File Inclusion in the file parameter. Rated high severity (CVSS 7.

CVE-2023-22584 HIGH
7.5 Jun 11

The Danfoss AK-EM100 stores login credentials in cleartext. Rated high severity (CVSS 7.5), this vulnerability is remote

CVE-2023-22585 MEDIUM
6.1 Jun 11

The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting in the title parameter. Rated medium seve

CVE-2023-22582 MEDIUM
6.1 Jun 11

The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting. Rated medium severity (CVSS 6.1), this v

CVE-2023-25912 MEDIUM
5.3 Jun 11

The webreport generation feature in the Danfoss AK-EM100 allows an unauthorized actor to generate a web report that disc

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy