Skip to main content

H3C Magic NX15 CVE-2025-3540

HIGH
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') (CWE-74)
2025-04-13 cna@vuldb.com
8.6
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
8.6 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 18:36 vuln.today
CVE Published
Apr 13, 2025 - 23:15 nvd
HIGH 8.6

DescriptionCVE.org

A vulnerability classified as critical was found in H3C Magic NX15, Magic NX30 Pro, Magic NX400 and Magic R3010 up to V100R014. Affected by this vulnerability is the function FCGI_WizardProtoProcess of the file /api/wizard/getCapability of the component HTTP POST Request Handler. The manipulation leads to command injection. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component.

AnalysisAI

A vulnerability classified as critical was found in H3C Magic NX15, Magic NX30 Pro, Magic NX400 and Magic R3010 up to V100R014. Rated high severity (CVSS 8.6), this vulnerability is low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-74. A vulnerability classified as critical was found in H3C Magic NX15, Magic NX30 Pro, Magic NX400 and Magic R3010 up to V100R014. Affected by this vulnerability is the function FCGI_WizardProtoProcess of the file /api/wizard/getCapability of the component HTTP POST Request Handler. The manipulation leads to command injection. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component.

Affected ProductsAI

See vendor advisory for affected versions.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2025-3540 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy