Skip to main content

Dir 823G Firmware CVE-2024-51024

HIGH
OS Command Injection (CWE-78)
2024-11-05 cve@mitre.org
8.0
CVSS 3.1 · Vendor: mitre
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 8.0 (HIGH). Attack characteristics: adjacent network attack vector, low complexity, low privileges required, no user interaction not required.

Exploit ScenarioDerived

An attacker could exploit this vulnerability to execute arbitrary operating system commands on the host.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 1.4% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

D-Link DIR_823G 1.0.2B05 was discovered to contain a command injection vulnerability via the HostName parameter in the SetWanSettings function. Rated high severity (CVSS 8.0), this vulnerability is low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. D-Link DIR_823G 1.0.2B05 was discovered to contain a command injection vulnerability via the HostName parameter in the SetWanSettings function. This vulnerability allows attackers to execute arbitrary OS commands via a crafted request. Affected products include: Dlink Dir-823G Firmware.

Know when Dir 823G Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (mitre) PRIMARY 8.0 HIGH
AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from Vendor (mitre) · only source for this CVE.

CVSS VectorVendor: mitre

Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionCVE.org

D-Link DIR_823G 1.0.2B05 was discovered to contain a command injection vulnerability via the HostName parameter in the SetWanSettings function. This vulnerability allows attackers to execute arbitrary OS commands via a crafted request.

Threat Intelligence Overview

EPSS Score
1.4%
Top 31% exploitable
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 1.4%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

41
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +40
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Affected Products (CPE)CVE.org

cpe:2.3:o:dlink:dir-823g_firmware:1.0.2b05:*:*:*:*:*:*:*
CVE-2020-25368 CRITICAL POC
9.8 Nov 04

A command injection vulnerability was discovered in the HNAP1 protocol in D-Link DIR-823G devices with firmware V1.0.2B0

CVE-2020-25367 CRITICAL POC
9.8 Nov 04

A command injection vulnerability was discovered in the HNAP1 protocol in D-Link DIR-823G devices with firmware V1.0.2B0

CVE-2023-43241 CRITICAL POC
9.8 Sep 21

D-Link DIR-823G v1.0.2B05 was discovered to contain a stack overflow via parameter TXPower and GuardInt in SetWLanRadioS

CVE-2023-43235 CRITICAL POC
9.8 Sep 21

D-Link DIR-823G v1.0.2B05 was discovered to contain a stack overflow via parameter StartTime and EndTime in SetWifiDownS

CVE-2023-26616 CRITICAL POC
9.8 Jun 29

D-Link DIR-823G firmware version 1.02B05 has a buffer overflow vulnerability, which originates from the URL field in Set

CVE-2023-26613 CRITICAL POC
9.8 Jun 29

An OS command injection vulnerability in D-Link DIR-823G firmware version 1.02B05 allows unauthorized attackers to execu

CVE-2023-26612 CRITICAL POC
9.8 Jun 29

D-Link DIR-823G firmware version 1.02B05 has a buffer overflow vulnerability, which originates from the HostName field i

CVE-2023-29665 CRITICAL POC
9.8 Apr 17

D-Link DIR823G_V1.0.2B05 was discovered to contain a stack overflow via the NewPassword parameters in SetPasswdSettings.

CVE-2022-44808 CRITICAL POC
9.8 Nov 22

A command injection vulnerability has been found on D-Link DIR-823G devices with firmware version 1.02B03 that allows an

CVE-2022-44201 CRITICAL POC
9.8 Nov 22

D-Link DIR823G 1.02B05 is vulnerable to Commad Injection. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2022-43109 CRITICAL POC
9.8 Nov 03

D-Link DIR-823G v1.0.2 was found to contain a command injection vulnerability in the function SetNetworkTomographySettin

CVE-2019-7297 CRITICAL POC
9.8 Jan 31

An issue was discovered on D-Link DIR-823G devices with firmware through 1.02B03. Rated critical severity (CVSS 9.8), th

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy