Skip to main content

Vap11G 300 Firmware CVE-2024-46330

HIGH
OS Command Injection (CWE-78)
2024-09-26 cve@mitre.org
7.4
CVSS 3.1 · Vendor: mitre
Share

Severity by source

Vendor (mitre) PRIMARY
7.4 HIGH
AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H

Primary rating from Vendor (mitre) · only source for this CVE.

CVSS VectorVendor: mitre

CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
Low
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Sep 26, 2024 - 14:15 cve.org
HIGH 7.4

DescriptionCVE.org

VONETS VAP11G-300 v3.3.23.6.9 was discovered to contain a command injection vulnerability via the iptablesWebsFilterRun object.

AnalysisAI

VONETS VAP11G-300 v3.3.23.6.9 was discovered to contain a command injection vulnerability via the iptablesWebsFilterRun object. Rated high severity (CVSS 7.4), this vulnerability is low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. VONETS VAP11G-300 v3.3.23.6.9 was discovered to contain a command injection vulnerability via the iptablesWebsFilterRun object. Affected products include: Vonets Vap11G-300 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.

CVE-2024-39791 CRITICAL
10.0 Aug 12

Stack-based buffer overflow vulnerabilities affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, so

CVE-2024-39815 CRITICAL
9.4 Aug 12

Improper check or handling of exceptional conditions vulnerability affecting Vonets industrial wifi bridge relays and wi

CVE-2024-37023 CRITICAL
9.4 Aug 12

Multiple OS command injection vulnerabilities affecting Vonets industrial wifi bridge relays and wifi bridge repeaters,

CVE-2024-29082 HIGH
8.8 Aug 12

Improper access control vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software

CVE-2024-41936 HIGH
8.7 Aug 12

A directory traversal vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software v

CVE-2024-41161 HIGH
8.7 Aug 08

Use of hard-coded credentials vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, so

CVE-2024-46329 HIGH
8.0 Sep 26

VONETS VAP11G-300 v3.3.23.6.9 was discovered to contain a command injection vulnerability via the SystemCommand object.

CVE-2024-46328 HIGH
8.0 Sep 26

VONETS VAP11G-300 v3.3.23.6.9 was discovered to contain hardcoded credentials for several different privileged accounts,

CVE-2024-42001 MEDIUM
6.1 Aug 12

An improper authentication vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, softw

CVE-2024-46327 MEDIUM
5.7 Sep 26

An issue in the Http_handle object of VONETS VAP11G-300 v3.3.23.6.9 allows attackers to access sensitive files via a dir

Share

CVE-2024-46330 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy