Xiongmai AHB7804R-MH-V2 CVE-2024-3765

CRITICAL
Improper Access Control (CWE-284)
2024-04-14 cna@vuldb.com
9.8
CVSS 3.1 · Vendor: vuldb
Share

Severity by source

Vendor (vuldb) PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from Vendor (vuldb) · only source for this CVE.

CVSS VectorVendor: vuldb

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Apr 14, 2024 - 23:15 cve.org
CRITICAL 9.8

DescriptionCVE.org

A vulnerability classified as critical was found in Xiongmai AHB7804R-MH-V2, AHB8004T-GL, AHB8008T-GL, AHB7004T-GS-V3, AHB7004T-MHV2, AHB8032F-LME and XM530_R80X30-PQ_8M. Affected by this vulnerability is an unknown functionality of the component Sofia Service. The manipulation with the input ff00000000000000000000000000f103250000007b202252657422203a203130302c202253657373696f6e494422203a202230783022207d0a leads to improper access controls. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260605 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

AnalysisAI

A vulnerability classified as critical was found in Xiongmai AHB7804R-MH-V2, AHB8004T-GL, AHB8008T-GL, AHB7004T-GS-V3, AHB7004T-MHV2, AHB8032F-LME and XM530_R80X30-PQ_8M. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-284. A vulnerability classified as critical was found in Xiongmai AHB7804R-MH-V2, AHB8004T-GL, AHB8008T-GL, AHB7004T-GS-V3, AHB7004T-MHV2, AHB8032F-LME and XM530_R80X30-PQ_8M. Affected by this vulnerability is an unknown functionality of the component Sofia Service. The manipulation with the input ff00000000000000000000000000f103250000007b202252657422203a203130302c202253657373696f6e494422203a202230783022207d0a leads to improper access controls. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260605 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Affected ProductsAI

See vendor advisory for affected versions.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2024-3765 vulnerability details – vuln.today